ArticleDer Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft2018
[Optical quality of three trifocal intraocular lens models : An optical bench comparison].
Article in Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Comparison of the optical behaviour of five different multifocal diffractive intraocular lenses in a model eye.Scientific reports · 2023Article
- Presbyopia correction after previous Intracor treatment: Combined implantation of a small-aperture and a non-diffractive extended-depth-of-focus lens.American journal of ophthalmology case reports · 2022Article
- [Unilateral implantation of a new extended range of vision intraocular lens in a young patient].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2022Article
- Unilateral implantation of a new non-diffractive extended range-of-vision IOL in a young patient with Curschmann-Steinert myotonic dystrophy.American journal of ophthalmology case reports · 2021Article
- Reversibility of the duet procedure: Bilateral exchange of a supplementary trifocal sulcus-fixated intraocular lens for correction of a postoperative refractive error.American journal of ophthalmology case reports · 2020Article
- Ray propagation imaging and optical quality evaluation of different intraocular lens models.PloS one · 2020Article
- Model of the light sword intraocular lens: in-vitro comparative studies.Biomedical optics express · 2020Article
- Bilateral trifocal IOL implantation in a pediatric case of cataract following steroid-therapy for acute lymphoblastic leukemia.American journal of ophthalmology case reports · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundKnowledge of the optical quality of different trifocal intraocular lenses (IOL) is important in customized patient care.
objectiveDifferent trifocal IOL were compared regarding their optical quality. MATERIALS AND
methodsWe analyzed the FineVision (PhysIOL, Liège, Belgium), the AT LISA tri 839MP (Zeiss, Oberkochen, Germany), and the AcrySofIQ PanOptix (Alcon, Fort Worth, TX, USA) with a power of +21D for the distance using the OptiSpheric IOL PRO optical bench (Trioptics, Wedel, Germany). The additions for the near and intermediate distances were as follows: +3.5D/+1.75D (FineVision), +3.33D/+1.66D (AT LISA tri), and + 3,25D/+ 2,17D (PanOptix). We evaluated the modulation transfer function (MTF) at a spatial frequency of 50lp/mm and the Strehl ratio using 3‑ (photopic) and 4.5-mm (mesopic) apertures.
resultsThe MTF at 50 lp/mm (FineVision/AT Lisa tri/PanOptix) at the far focus was 0.373/0.399/0.400 (3-mm aperture) and 0.512/0.311/0.243 (4.5-mm aperture). At the intermediate focus, the MTF was 0.162/0.147/0.153 (3-mm aperture) and 0.092/0.125/0.137 (4.5-mm aperture). The MTF at the near focus was 0.229/0.192/0.404 (3-mm aperture) and 0.217/0.212/0.169 (4.5-mm aperture). The Strehl ratio was 0.335/0.298/0.370 (3-mm aperture) and 0.243/0.180/0.270 (4.5-mm aperture) at the far focus. At intermediate distances, the Strehl ratio was 0.189/0.185/0.162 (3-mm aperture) and 0.099/0.097/0.114 (4.5-mm aperture). The Strehl ratio was 0.305/0.283/0.464 (3-mm aperture) and 0.177/0.181/0.155 (4.5-mm aperture) at the near focus.
conclusionEvaluation of the three trifocal IOL models at the optical bench could show distinct peaks at the far, intermediate, and near focus. The results were comparable in terms of optical performance.
Indexed as
Identifiers
28956141What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.