ArticleHip & pelvis2017
Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up.
Article in Hip & pelvis, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 18 citations in OpenAlex.
- The use of porous titanium acetabular augments in primary total hip arthroplasty for hip dysplasia or rapidly destructive coxopathy.Bone & joint open · 2025Article
- Reconstruction of severe acetabular defects (Paprosky type III A) in total hip arthroplasty using modular tantalum augments in combination with a cemented cup.International orthopaedics · 2024Article
- The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium.HSS journal : the musculoskeletal journal of Hospital for Special Surgery · 2022Review
- A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report.Case reports in orthopedics · 2022Article
- Long-term results of combined porous tantalum augments and titanium-coated cups for Paprosky type III bone defects in acetabular revision.International orthopaedics · 2021Article
- Platelet-Rich Plasma Pretreatment on Grit-Blasted Titanium Alloy for Enhanced Osteogenic Differentiation of Human Adipose-Derived Stem Cells.Clinics in orthopedic surgery · 2019Article
- An alternative treatment option for Paprosky Type IIIb acetabular defect using multiple tantalum wedges - A case report.Journal of clinical orthopaedics and traumaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeHigh rates of mechanical failure have been reported in type III acetabular defects. Recently porous trabecular metal augments have been introduced with, excellent biomechanical characteristics and biocompatibility, allowing early stability and greater bone ingrowth. The aim of the study was to assess the short term clinical and radiological outcome of the trabecular metal augments. MATERIALS AND
methodsWe performed, 22 revision total hip arthroplasties (THA) and 6 primary THA (total 28) using trabecular metal augments to reconstruct acetabular defect between 2011 to 2015. Among 28 patients, 18 were males, 10 females. Mean age of patients was 61.21 years. Paprosky classification for acetabular bone defects was used. Eighteen cases were classified as grade 3 A and 10 cases as grade 3B. Hip center was calculated in each case preoperatively and compared postoperatively to check whether it has been brought down. Clinical outcome assessed using Harris hip score (HHS) and radiological outcomes as osteolysis in acetabular zones and osseointegration, according to Moore's criteria.
resultsHHS improved from 58.00 to 86.20. Centre of rotation of hip joint corrected from 38.90 mm preoperatively to 23.85 mm postoperatively above the interteardrop line. Among 28 patients, 18 patients had three or more signs of osseointegration (Moore's criteria), during final follow up and 10 had one/two signs. No radiolucency, osteolysis, or loosening found during follow up radiographic examination.
conclusionOur study showed that trabecular metal augments were highly satisfactory in short term. However, long term study is required for better evaluation.