ArticleJournal of clinical orthopaedics and trauma
Management of unstable pertrochanteric fractures with proximal femoral locking compression plates and affect of neck-shaft angle on functional outcomes.
Article in Journal of clinical orthopaedics and trauma. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 9 citations in OpenAlex.
- Modifying the reduction quality criteria of the Baumgaertner classification may increase its performance in predicting mechanical failure after intertrochanteric nailing.OTA international : the open access journal of orthopaedic trauma · 2025Article
- Article
- Evaluation of the effect of proximal femur geometry on results of geriatric intertrochanteric fracture surgery.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2022Article
- Article
- Femoral Neck Shaft Angle and Management of Proximal Femur Fractures: Is the Contralateral Femur a Reliable Template?Journal of orthopaedic trauma · 2021Article
- [Effectiveness comparison between proximal femoral nail anti-rotation and proximal femoral locking compression plate for intertrochanteric fracture in elderly patients combined with hemiplegia due to cerebral infarction].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2018Article
- Controlled study on Gamma nail and proximal femoral locking plate for unstable intertrochanteric femoral fractures with broken lateral wall.Scientific reports · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundManagement of unstable pertrochanteric fractures remains a challenge with various implant choices. Intramedullary devices are usually preferred for the management of the unstable fractures. When nailing is unsuitable for the configuration of the fracture extra medullary procedures are preferred. PFLCP is a contact limited implant that allows multiple angularly stable fixations with preserving more bone stock after implantation as an extramedullary implant. There are only a few reports in the literature about the osteosynthesis of unstable trochanteric fractures with proximal femoral locking compression plates and their results are conflicting. In the present study we aimed to evaluate the functional and radiological outcomes of proksimal femoral locking compression plates in open reduction and internal fixation of AO/OTA 31A2-2 and 3 fractures.
methodsPatients older than 18 years of age with a minimum follow-up time of 1 year matching the inclusion criteria retrospectively evaluated. Patients' demographics, Singh index, intra and post-operative data, mobilization and union time gathered from the patients' files. Baumgaertner modified criteria of fracture reduction was used to assess the post-operative reduction quality. Early and last follow-up radiographs were used to evaluate malunion and change in neck- shaft angle. Final clinical outcome was assessed using the Harris Hip scoring system.
results18 male and 13 female patients with the mean age of 74 (46-88) met the inclusion criteria. Reduction quality according to Baumgaertner modified criteria was good in 25 patients and acceptable in 6. Mean union time was 21.53 ± 4.18 weeks. There was neither non-union nor malunion. The mean neck-shaft angle change was -3.1° ± 2.16°. The mean HHS was 77.90 ± 4.84 and there was no significance in HHS according to reduction quality and change in neck-shaft angle (p = 0.385, p = 0.0059). HHS was negatively correlated with age, mobilization time and, longer union time (p < 0.05). There was no correlation between Singh index and reduction quality (p = 0.865). Singh index was only correlated with the patient's age (p = 0.000, rho = -0.595). There were 2 infections and, 2 backing of the proximal screws.
conclusionEven though PFLCP is not the first choice in management of unstable pertrochanteric fractures, it must be kept in mind as an alternative to the other conventional plates and intramedullary implants with the properties of an increased stability by multiaxial screw locking and the results are satisfactory when appropriate settlement achieved.