Towards Robot-Assisted Retinal Vein Cannulation: A Motorized Force-Sensing Microneedle Integrated with a Handheld Micromanipulator
Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 42 citations in OpenAlex.
- Technical advances in robotic retinal surgery: a systematic review and future research directions.Journal of robotic surgery · 2026Review
- Robotising vitreoretinal surgeries.Eye (London, England) · 2025Review
- Integrated Piezoelectric Vibration and In Situ Force Sensing for Low-Trauma Tissue Penetration.Cyborg and bionic systems (Washington, D.C.) · 2025Article
- A Review of Recent Advancements in Sensor-Integrated Medical Tools.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Microsurgery Robots: Applications, Design, and Development.Sensors (Basel, Switzerland) · 2023Review
- Investigation of High-Resolution Distributed Fiber Sensing System Embedded in Flexible Silicone Carpet for 2D Pressure Mapping.Sensors (Basel, Switzerland) · 2022Article
- Review
- Robotic Assistance for Intraocular Microsurgery: Challenges and Perspectives.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022Article
- Force and Velocity Based Puncture Detection in Robot Assisted Retinal Vein Cannulation: In-Vivo Study.IEEE transactions on bio-medical engineering · 2022Article
- Microneedle-based ocular drug delivery systems - recent advances and challenges.Beilstein journal of nanotechnology · 2022Review
- Automated Retinal Vein Cannulation on Silicone Phantoms Using Optical-Coherence-Tomography-Guided Robotic Manipulations.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2021Article
- Tool-tissue forces in surgery: A systematic review.Annals of medicine and surgery (2012) · 2021Review
- A Comparison of Manual and Robot Assisted Retinal Vein Cannulation in Chicken Chorioallantoic Membrane.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2020Article
- Dual-Stiffness Force-Sensing Cannulation Tool for Retinal Microsurgery.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2019Article
- Evaluation of a Force-Sensing Handheld Robot for Assisted Retinal Vein Cannulation.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called "Micron", with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation.