Evidence map›Paper›PMID 28945699›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2017

Effects of Nano-Hydroxyapatite/Polyetheretherketone-Coated, Sandblasted, Large-Grit, and Acid-Etched Implants on Inflammatory Cytokines and Osseointegration in a Peri-Implantitis Model in Beagle Dogs.

Hua-Wei Yang, Xiao-Shan Tang, Zhuo-Wei Tian, Yang Wang, Wen-Yi Yang, Jing-Zhou Hu

RetractedOpen access · hybridAbstract readRetracted Publication
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hua-Wei YangDepartment of Stomatology, Shanghai Tenth People's Hospital of Tongji University, Shanghai, China (mainland).
Xiao-Shan TangDepartment of Stomatology, Shanghai Tenth People's Hospital of Tongji University, Shanghai, China (mainland).
Zhuo-Wei TianDepartment of Oral and Maxillofacial-Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China (mainland).
Yang WangDepartment of Oral and Maxillofacial-Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China (mainland).
Wen-Yi YangDepartment of Oral and Maxillofacial-Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China (mainland).
Jing-Zhou HuDepartment of Oral and Maxillofacial-Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China (mainland).
Shanghai Jiao Tong University · CNShanghai Ninth People's Hospital · CNTongji University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND This study explored the effects of nano-hydroxyapatite/polyetheretherketone (n-HA/PEEK)- coated sandblasted, large-grit, and acid-etched (SLA) implants on inflammatory cytokines and osseointegration in peri-implantitis model beagle dogs. MATERIAL AND METHODS Peri-implantitis models were established. Eight beagle dogs were randomly and evenly assigned into SLA tied, SLA + n-HA/PEEK tied, SLA untied, or SLA + n-HA/PEEK untied groups. A special periodontal probe was used to detect the plaque index (PLI), probing depth (PD), and modified Sulcus Bleeding Index (mSBI). Gingival crevicular fluid was collected and an ELISA kit was utilized to detect IL-1, IL-6, and IL-17 levels. The colony-forming units were counted and the maximum shear strength of implants was tested using the axial pullout test. HE staining was used to detect the inflammation of peri-implant bone tissues. Osseointegration was observed through toluidine blue staining. Bone-to-implant contact (BIC) was obtained through histological observation and the mineral apposition rate (MAR) was calculated after immune fluorescent double staining. RESULTS The SLA tied group demonstrated higher levels of PLI, PD, mSBI, IL-1, IL-6, and IL-17 and a higher degree of inflammation than the SLA + n-HA/PEEK tied group. The tied groups also displayed similar results over the untied groups at the same time point. The maximum shear strength, BIC, and MAR in the SLA tied group were significantly lower than in the SLA + n-HA/PEEK tied group. CONCLUSIONS Our findings demonstrate that SLA + n-HA/PEEK implants can promote osseointegration and relieve the inflammation response of peri-implantitis in beagle dogs.

Indexed as

Acid Etching, DentalDental ImplantsAnimalsBenzophenonesBone and BonesColony-Forming Units AssayCytokinesDental PlaqueDisease Models, AnimalDogsDurapatiteInflammationInflammation MediatorsKetonesMineralsNanoparticlesBenzophenonesCytokinesDental ImplantsDurapatiteInflammation MediatorsKetonesMineralspolyetheretherketonePolyethylene GlycolsPolymers

Identifiers

PMID28945699
PMCPMC5628887
OpenAlexW2757571254

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.