Evidence map›Paper›PMID 28944706›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2017

Flexible lateral isocenter: A novel mechanical functionality contributing to dose reduction in neurointerventional procedures.

Ljubisa Borota, Andreas Patz

Open access · hybridAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ljubisa Borota1 Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
Andreas Patz2 Toshiba Medical Systems Europe, Zoetermeer, the Netherlands.
Uppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim of the study A new functionality that enables vertical mobility of the lateral arm of a biplane angiographic machine is referred to as the flexible lateral isocenter. The aim of this study was to analyze the impact of the flexible lateral isocenter on the air-kerma rate under experimental conditions. Material and methods An anthropomorphic head-and-chest phantom with anteroposterior (AP) diameter of the chest varying from 22 cm to 30 cm simulated human bodies of different body constitutions. The angulation of the AP arm in the sagittal plane varied from 35 degrees to 55 degrees for each AP diameter. The air-kerma rate (mGy/min) values were read from the system dose display in two settings for each angle: flexible lateral isocenter and fixed lateral isocenter. Results The air-kerma rate was significantly lower for all AP diameters of the chest of the phantom when the flexible lateral isocenter was used: (a) For 22 cm, the p value was 0.028; (b) For 25 cm, the p value was 0.0169; (c) For 28 cm, the p value was 0.01005 and (d) For 30 cm, the p value was 0.01703. Conclusion Our results show that the flexible lateral isocenter contributes significantly to the reduction of the air-kerma rate, and thus to a safer environment in terms of dose lowering both for patients and staff.

Indexed as

Cerebral AngiographyEquipment DesignHumansPhantoms, ImagingRadiation Dosagebiplane angiographic machinedose savingLateral isocenter

Identifiers

PMID28944706
PMCPMC5814073
OpenAlexW2760748047

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.