Localization of cardiac volume and patient features in inverse geometry x-ray fluoroscopy.

Michael A Speidel, Jordan M Slagowski, David A P Dunkerley, Martin Wagner, Tobias Funk, Amish N Raval

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 97% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Michael A SpeidelDept. of Medical Physics, University of Wisconsin, Madison, WI, USA.
Jordan M SlagowskiDept. of Medical Physics, University of Wisconsin, Madison, WI, USA.
David A P DunkerleyDept. of Medical Physics, University of Wisconsin, Madison, WI, USA.
Martin WagnerDept. of Medical Physics, University of Wisconsin, Madison, WI, USA.
Tobias FunkTriple Ring Technologies, Inc., Newark, CA, USA.
Amish N RavalDept. of Medicine, University of Wisconsin, Madison, WI, USA.
University of Wisconsin–Madison · USTriple Ring Technologies (United States) · US

Funding

Low-Dose Tomosynthetic Interventional System For Quantitative Cardiac ImagingR01HL084022 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI SPEIDEL, MICHAEL A · 2007 to 2015
$4.4M
NHLBI NIH HHS R01 HL084022
6 · The paper itself

Abstract

The scanning-beam digital x-ray (SBDX) system is an inverse geometry x-ray fluoroscopy technology that performs real-time tomosynthesis at planes perpendicular to the source-detector axis. The live display is a composite image which portrays sharp features (e.g. coronary arteries) extracted from a 16 cm thick reconstruction volume. We present a method for automatically determining the position of the cardiac volume prior to acquisition of a coronary angiogram. In the algorithm, a single non-contrast frame is reconstructed over a 44 cm thickness using shift-and-add digital tomosynthesis. Gradient filtering is applied to each plane to emphasize features such as the cardiomediastinal contour, diaphragm, and lung texture, and then sharpness vs. plane position curves are generated. Three sharpness metrics were investigated: average gradient in the bright field, maximum gradient, and the number of normalized gradients exceeding 0.5. A model correlating the peak sharpness in a non-contrast frame and the midplane of the coronary arteries in a contrast-enhanced frame was established using 37 SBDX angiographic loops (64-136 kg human subjects, 0-30° cranial-caudal). The average gradient in the bright field (primarily lung) and the number of normalized gradients >0.5 each yielded peaks correlated to the coronary midplane. The rms deviation between the predicted and true midplane was 1.57 cm. For a 16 cm reconstruction volume and the 5.5-11.5 cm thick cardiac volumes in this study, midplane estimation errors of 2.25-5.25 cm were tolerable. Tomosynthesis-based localization of cardiac volume is feasible. This technique could be applied prior to coronary angiography, or to assist in isocentering the patient for rotational angiography.

Indexed as

interventional cardiologyinverse geometryscanning-beam digital x-raytomosynthesisx-ray fluoroscopy

Identifiers

PMID28943697
PMCPMC5606251
OpenAlexW2594043006

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.