Evidence map›Paper›PMID 28942521›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2017

Imaging of tangential traction types in lamellar macular holes.

Alessandra Acquistapace, Matteo Giuseppe Cereda, Mario Cigada, Giovanni Staurenghi, Ferdinando Bottoni

Abstract read
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Primary Lamellar Macular Holes: To Vit or Not to Vit.Journal of clinical medicine · 2022
    Review
  3. Multimodal Imaging of Lamellar Macular Holes.Journal of ophthalmology · 2021
    Review
  4. Observational
  5. Lamellar macular holes: monitoring and management strategies.Clinical ophthalmology (Auckland, N.Z.) · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Alessandra AcquistapaceEye Clinic, Department of Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy. alessandra.acquistapace@gmail.com.ORCID http://orcid.org/0000-0003-1784-4632
Matteo Giuseppe CeredaEye Clinic, Department of Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy.
Mario CigadaEye Clinic, Department of Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy.
Giovanni StaurenghiEye Clinic, Department of Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy.
Ferdinando BottoniEye Clinic, Department of Clinical Science "Luigi Sacco", Sacco Hospital, University of Milan, Milan, Italy.
University of Milan · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo determine the best imaging procedure for the definition of tangential tractions generated by epiretinal membranes in lamellar macular holes.

methodsInclusion criteria were a diagnosis of lamellar macular hole with tractional epiretinal membranes based upon fundus autofluorescence (FAF), and spectral-domain optical coherence tomography (SD-OCT) imaging (HRA + OCT Spectralis, Heidelberg Engineering, Heidelberg, Germany). Tangential tractions were evaluated with infrared reflectance (IR; 820 nm) and OCT en face (193 B-scans, 30 × 20°pattern size, 31 μm between two consecutive B-scans). Three different categories of tangential traction were previously defined: 1) unidirectional, 2) pluridirectional, and 3) concentric. Two independent masked physicians evaluated the images in order to categorize the type of tangential traction either with IR and OCT (en face) for every single patient. Cohen's kappa statistic was used to evaluate inter-observer and inter-instrument agreement.

resultsTwenty eyes of 19 patients were included in the study. Inter-observer OCT test showed almost perfect agreement between examiners (κ = 0.86). Inter-observer IR test showed substantial agreement (κ = 0.7). Inter-instrument agreement was fair for both observers, respectively κ = 0.35 for observer 1 and κ = 0.22 for observer 2. Intra-observer agreement was almost perfect for OCT (κ = 0.93) and substantial for IR (κ = 0.78).

conclusionTangential traction associated with epiretinal membranes in lamellar macular holes can be successfully evaluated by OCT en face and IR reflectance. Inter-observer concordance is high for both instruments. However, high inter-instrument discordance is present. Therefore, the gold standard imaging technique for differentiating the different types of contraction in epiretinal membranes has still to be determined.

Indexed as

AgedAged, 80 and overDiagnostic ImagingEpiretinal MembraneFemaleFluorescein AngiographyFundus OculiHumansMacula LuteaMaleMiddle AgedReproducibility of ResultsRetinal PerforationsROC CurveTomography, Optical CoherenceVisual AcuityEpiretinal membraneInfrared reflectanceLamellar macular holeSpectral-domain optical coherence tomographyTangential traction

Identifiers

PMID28942521
OpenAlexW2758919959

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.