Evidence map›Paper›PMID 28941247›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2018

Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Kevin J Warburton, John B Everingham, Jillian L Helms, Andrew J Kazanovicz, Katherine A Hollar, Jeff D Brourman, Steven M Fox, Trevor J Lujan

Abstract readEvaluation Study
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Quantifying wear depth in hip prostheses using a 3D optical scanner.Wear : an international journal on the science and technology of friction lubrication and wear · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kevin J WarburtonBoise State University, 1910 University Drive, Boise, 83725-2085, Idaho.
John B EveringhamBoise State University, 1910 University Drive, Boise, 83725-2085, Idaho.
Jillian L HelmsBoise State University, 1910 University Drive, Boise, 83725-2085, Idaho.
Andrew J KazanoviczSecuros Surgical, 443 Main Street, Fiskdale, 01518, Massachusetts.
Katherine A HollarBoise State University, 1910 University Drive, Boise, 83725-2085, Idaho.
Jeff D BrourmanWestVet Animal Emergency and Specialty Center, 5019 N. Sawyer Ave., Garden City, 83714, Idaho.
Steven M FoxSecuros Surgical, 443 Main Street, Fiskdale, 01518, Massachusetts.
Trevor J LujanBoise State University, 1910 University Drive, Boise, 83725-2085, Idaho.

Funding

VPS35 D620N inhibits autophagy through disrupted hyaluronic acid-CD44 signalingP20GM109095 · NIGMS · BOISE STATE UNIVERSITY · PI OXFORD, JULIA THOM · 2014 to 2023
$22.7M
NIGMS NIH HHS P20 GM109095
6 · The paper itself

Abstract

Hip resurfacing offers advantages for young, active patients afflicted with hip osteoarthritis and may also be a beneficial treatment for adult canines. Conventional hip resurfacing uses metal-on-metal bearings to preserve bone stock, but it may be feasible to use metal-on-polyethylene bearings to reduce metal wear debris while still preserving bone. This study characterized the short-term wear behavior of a novel hip resurfacing implant for canines that uses a 1.5 mm thick liner of highly cross-linked polyethylene in the acetabular component. This implant was tested in an orbital bearing machine that simulated canine gait for 1.1 million cycles. Wear of the liner was evaluated using gravimetric analysis and by measuring wear depth with an optical scanner. The liners had a steady-state mass wear rate of 0.99 ± 0.17 mg per million cycles and an average wear depth in the central liner region of 0.028 mm. No liners, shells, or femoral heads had any catastrophic failure due to yielding or fracture. These results suggest that the thin liners will not prematurely crack after implantation in canines. This is the first hip resurfacing device developed for canines, and this study is the first to characterize the in vitro wear of highly cross-linked polyethylene liners in a hip resurfacing implant. The canine implant developed in this study may be an attractive treatment option for canines afflicted with hip osteoarthritis, and since canines are the preferred animal model for human hip replacement, this implant can support the development of metal-on-polyethylene hip resurfacing technology for human patients. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1196-1205, 2018.

Indexed as

AnimalsArthroplastyDogsHip JointHip ProsthesisPolyethylenePolyethylenecross-linked polyethylenedoggravimetricship simulatorsurface wear

Identifiers

PMID28941247
PMCPMC5866242

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.