Evidence map›Paper›PMID 28937273›Full record

ArticleThe British journal of radiology2018

Cone-beam CT acquisition during transradial TACE made easy; use of the swivel arm board.

Uei Pua, Chia Chia Teo, Pe Thet U, Lawrence Han Hwee Quek

Abstract read
In one paragraph

Article in The British journal of radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Uei Pua1 Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore City, Singapore.
Chia Chia Teo1 Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore City, Singapore.
Pe Thet U1 Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore City, Singapore.
Lawrence Han Hwee Quek1 Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore City, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTransradial access for peripheral intervention often requires certain modification from its coronary counterparts. One of the challenges during transradial transarterial chemoembolization (TACE) is the need for the access arm to be repositioned during cone-beam CT (CBCT) acquisition to allow for C-arm rotation. We recently introduced a swivel arm board to allow seamless repositioning of the access arm during and after CBCT acquisition. The purpose of this study is to detail the technique and feasibility of this useful adjunct to transradial TACE.

methodsWe performed a retrospective study of consecutive cases of transradial TACE between November 2015 and March 2016, which represented the period where we introduced the swivel arm board to our transradial procedure. A total of 20 transradial TACE using the swivel arm board was performed in 17 patients. There were 13 males and 4 females. The mean age was 69.5 years old (range 48-82 years). Indications for TACE included hepatocellular carcinoma (n = 14) and metastatic liver disease (n = 3).

resultsTransradial TACE was successful in all cases. A total of 40 successful arm repositioning using the swivel arm board for CBCT acquisitions were performed (100% success rate). There was no catheter or sheath dislodgement associated with the arm movements. No change in the microcatheter tip position was detected as a result of the arm repositioning. Hemostasis was successfully achieved in all the patients. There was no access related complication.

conclusionThe swivel arm board is a useful adjunct to enable CBCT acquisition during transradial TACE. Advances in knowledge: Transradial TACE is a novel technique, and adaptation to allow for CBCT acquisition is currently challenging. This manuscript illustrates how to overcome the positioning difficulties with the use of the swivel arm board.

Indexed as

Cone-Beam Computed TomographyAdultAgedAged, 80 and overCarcinoma, HepatocellularChemoembolization, TherapeuticFemaleHumansLiver NeoplasmsMaleMiddle AgedRetrospective Studies

Identifiers

PMID28937273
PMCPMC5966202

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.