Evidence map›Paper›PMID 28936693›Full record

ArticleArchives of orthopaedic and trauma surgery2017

Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

M S H Beerekamp, M Backes, N W L Schep, D T Ubbink, J S Luitse, T Schepers, J C Goslings

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. [Calcaneal fractures-Current status and treatment approaches].Unfallchirurgie (Heidelberg, Germany) · 2026
    Review
  2. Article
  3. Intraoperative revision rates due to three-dimensional imaging in orthopedic trauma surgery: results of a case series of 4721 patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

M S H BeerekampTrauma Unit, Department of Surgery, Academic Medical Center, 1105 AZ, Amsterdam, The Netherlands. m.s.beerekamp@amc.nl.ORCID http://orcid.org/0000-0002-2692-782X
M BackesTrauma Unit, Department of Surgery, Academic Medical Center, 1105 AZ, Amsterdam, The Netherlands.
N W L SchepDepartment of Surgery, Maasstad Hospital, Rotterdam, The Netherlands.
D T UbbinkDepartment of Surgery, Academic Medical Center, Amsterdam, The Netherlands.
J S LuitseTrauma Unit, Department of Surgery, Academic Medical Center, 1105 AZ, Amsterdam, The Netherlands.
T SchepersTrauma Unit, Department of Surgery, Academic Medical Center, 1105 AZ, Amsterdam, The Netherlands.
J C GoslingsTrauma Unit, Department of Surgery, Academic Medical Center, 1105 AZ, Amsterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPrevious studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. PATIENTS AND

methodsIn this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone.

resultsA total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups.

conclusionIntra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of corrections performed after 2D-imaging when 3D imaging was available. No substantiation for cost reduction was found through reduction in peri-operative imaging or in terms of improved patient-relevant outcomes.

Indexed as

AdultCalcaneusFemaleFluoroscopyFracture Fixation, InternalFractures, BoneHumansImaging, Three-DimensionalMaleMiddle AgedMonitoring, IntraoperativeOpen Fracture ReductionTreatment Outcome2D-imaging3D-imagingCalcaneusFractureIntra-operative imaging

Identifiers

PMID28936693
PMCPMC5686243

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.