Evidence map›Paper›PMID 28934238›Full record

ArticlePloS one2017

A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients.

Th I Götz, G Lahmer, V Strnad, Ch Bert, B Hensel, A M Tomé, E W Lang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Systematic review of artificial intelligence in brachytherapy.Journal of contemporary brachytherapy · 2026
    Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Th I GötzCIML, Biophysics, University of Regensburg, 93040 Regensburg, Germany.ORCID http://orcid.org/0000-0001-8751-3404
G LahmerDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
V StrnadDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
Ch BertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
B HenselCenter for Medical Physics and Engineering, University of Erlangen-Nuremberg, 91052 Erlangen, Germany.
A M ToméIEETA, DETI, Universidade de Aveiro, 3810-193 Aveiro, Portugal.
E W LangCIML, Biophysics, University of Regensburg, 93040 Regensburg, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DEUniversity of Aveiro · PTUniversity of Regensburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient's anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements. The current study develops an automatic analysis tool of EMT data sets recorded with a solenoid sensor to assure concordance of the source movement with the treatment plan. The tool combines machine learning techniques such as multi-dimensional scaling (MDS), ensemble empirical mode decomposition (EEMD), singular spectrum analysis (SSA) and particle filter (PF) to precisely detect and quantify any mismatch between the treatment plan and actual EMT measurements. We demonstrate that movement artifacts as well as technical signal distortions can be removed automatically and reliably, resulting in artifact-free reconstructed signals. This is a prerequisite for a highly accurate determination of any deviations of dwell positions from the treatment plan.

Indexed as

CathetersElectromagnetic PhenomenaRadiation DosageAgedAutomationBrachytherapyBreast NeoplasmsFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedMotionPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-Assisted

Identifiers

PMID28934238
PMCPMC5608198
OpenAlexW2760371514

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.