Evidence map›Paper›PMID 28929828›Full record

ArticleActa orthopaedica2017

Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements.

Oystein Gothesen, Stein Hakon L Lygre, Michelle Lorimer, Stephen Graves, Ove Furnes

Abstract readMulticenter Study
In one paragraph

Article in Acta orthopaedica, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Oystein Gothesena Norwegian Arthroplasty Register, Department of Orthopaedic Surgery , Haukeland University Hospital , Bergen.
Stein Hakon L Lygrea Norwegian Arthroplasty Register, Department of Orthopaedic Surgery , Haukeland University Hospital , Bergen.
Michelle Lorimere AOA (Australian Orthopaedic Association) National Joint Replacement Registry , SAHMRI (South Australia Health and Research Institute) , Adelaide , Australia.
Stephen Gravese AOA (Australian Orthopaedic Association) National Joint Replacement Registry , SAHMRI (South Australia Health and Research Institute) , Adelaide , Australia.
Ove Furnesa Norwegian Arthroplasty Register, Department of Orthopaedic Surgery , Haukeland University Hospital , Bergen.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose - Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods - Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 and 2014, were analyzed with aseptic loosening as primary end-point and all revisions as secondary end-point. We hypothesized that no difference would be found in the rate of revision between rotating-platform and the most used fixed-bearing TKRs, or between keeled and non-keeled tibia. Kaplan-Meier estimates and curves, and Cox regression relative risk estimates adjusted for age, sex, and diagnosis were used for comparison. Results - The rotating-platform TKRs had an increased risk of revision for aseptic loosening compared with the most used fixed-bearing knees, in Norway (RR =6, 95% CI 4-8) and Australia (RR =2.1, 95% CI 1.8-2.5). The risk of aseptic loosening as a reason for revision was highest in Norway compared with Australia (RR =1.7, 95% CI 1.4-2.0). The keeled tibial component had the same risk of aseptic loosening as the non-keeled tibia (Australia). Fixation method and subtypes of the tibial components had no impact on the risk of aseptic loosening in these mobile-bearing knees. Interpretation - The rotating-platform TKRs in this study appeared to have a higher risk of revision for aseptic loosening than the most used fixed-bearing TKRs.

Indexed as

RegistriesAgedArthroplasty, Replacement, KneeAustraliaFemaleHumansKnee ProsthesisMaleNorwayOsteoarthritis, KneePostoperative ComplicationsProsthesis DesignProsthesis FailureReoperation

Identifiers

PMID28929828
PMCPMC5694810

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.