Evidence map›Paper›PMID 28929204›Full record

ArticleInternational orthopaedics2018

Salvage of a monoblock metal-on-metal cup using a dual mobility liner: a two-year MRI follow-up study.

Maximilian F Kasparek, Lisa Renner, Martin Faschingbauer, Wenzel Waldstein, Kilian Rueckl, Friedrich Boettner

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 3 countries.

Maximilian F KasparekAdult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Lisa RennerOrthopaedic Department, Center for Musculoskeletal Surgery, Charité, Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
Martin FaschingbauerDepartment of Orthopedic Surgery, University Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany.
Wenzel WaldsteinDepartment of Orthopedics, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Kilian RuecklAdult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Friedrich BoettnerAdult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. boettnerf@hss.edu.
Hospital for Special Surgery · USCharité - Universitätsmedizin Berlin · DEMedical University of Vienna · ATUniversität Ulm · DEVienna General Hospital · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRevision of failed modular metal-on-metal total hip replacement (MoM-THA) can be technically difficult. A dual mobility liner can help to salvage a well-fixed acetabular component. The present paper reports the clinical and radiographic outcome of revision of failed Birmingham modular MoM-THA using a dual mobility liner.

methodsThe present study reports on ten patients (3 female and 7 male) with 11 revision THAs. Patients underwent revision an average of 51 months (range 40-73 months) after index procedure. Mean follow-up after the revision was 31 months (range 24-37 months) and all patients underwent an MRI with metal artifact reduction software (MARS) at least two years after revision to assess for local polyethylene wear and osteolysis.

resultsThe Harris Hip score improved from 92.2 (range 63.0-100.0) to 100.0 (p = 0.072). One patient had a one-time dislocation within seven days of surgery. No patient required additional surgeries. Radiographs showed no signs of component loosening and osteolysis and MRI imaging revealed no evidence of polyethylene wear or osteolysis.

conclusionA dual mobility liner in an existing Birmingham cup can provide excellent clinical and radiological short-term results without MRI evidence of increased polyethylene wear. Post-operative hip precautions should be enforced.

Indexed as

AdultAgedAged, 80 and overArthroplasty, Replacement, HipFemaleFollow-Up StudiesHip JointHip ProsthesisHumansMagnetic Resonance ImagingMaleMetal-on-Metal Joint ProsthesesMiddle AgedProsthesis DesignProsthesis FailureReoperationBirminghamDual mobility linerMetal-on-metalOsteolysisRevisionTotal hip arthroplasty

Identifiers

PMID28929204
OpenAlexW2755617860

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.