Evidence map›Paper›PMID 28926382›Full record

ArticleThe Journal of bone and joint surgery. American volume2017

Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants.

Gulraj S Matharu, Fiona Berryman, Andrew Judge, Aleksi Reito, Jamie McConnell, Olli Lainiala, Stephen Young, Antti Eskelinen, Hemant G Pandit, David W Murray

Open access · hybridAbstract readMulticenter StudyValidation Study
In one paragraph

Article in The Journal of bone and joint surgery. American volume, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
8.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it, 61 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Midterm results of the Birmingham hip resurfacing: a single-surgeon series.Archives of orthopaedic and trauma surgery · 2023
    Article
  11. Aluminum Nanoparticles Affect Human Platelet Function In Vitro.International journal of molecular sciences · 2023
    Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 2 countries.

Gulraj S Matharu1Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom 2The Royal Orthopaedic Hospital, Birmingham, United Kingdom 3MRC Lifecourse Epidemiology Unit, Southampton General Hospital, University of Southampton, Southampton, United Kingdom 4Coxa Hospital for Joint Replacement, Tampere, Finland 5Warwick Hospital, Warwick, United Kingdom 6Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), Chapel Allerton Hospital, Leeds, United Kingdom.
Fiona Berryman
Andrew Judge
Aleksi Reito
Jamie McConnell
Olli Lainiala
Stephen Young
Antti Eskelinen
Hemant G Pandit
David W Murray
Coxa Hospital · FINuffield Orthopaedic Centre · GBWarwick Hospital · GBChapel Allerton Hospital · GBRoyal Orthopaedic Hospital · GBSouthampton General Hospital · GB

Funding

Versus Arthritis 21006
6 · The paper itself

Abstract

backgroundThe authors of recent studies have reported newly devised implant-specific blood metal ion thresholds to predict adverse reactions to metal debris (ARMD) in patients who have undergone unilateral or bilateral metal-on-metal (MoM) hip arthroplasty. These thresholds were most effective for identifying patients at low risk of ARMD. We investigated whether these newly devised blood metal ion thresholds could effectively identify patients at risk of ARMD after MoM hip arthroplasty in an external cohort of patients.

methodsWe performed a validation study involving 803 MoM hip arthroplasties (323 unilateral Birmingham Hip Resurfacing [BHR], 93 bilateral BHR, and 294 unilateral Corail-Pinnacle implants) performed in 710 patients at 3 European centers. All patients underwent whole-blood metal ion sampling, and were divided into 2 groups: those with ARMD (leading to revision or identified on imaging; n = 75) and those without ARMD (n = 635). Previously devised implant-specific blood metal ion thresholds (2.15 μg/L of cobalt for unilateral BHR; 5.5 μg/L for the maximum of either cobalt or chromium for bilateral BHR; and 3.57 μg/L of cobalt for unilateral Corail-Pinnacle implants) were applied to the validation cohort, and receiver operating characteristic curve analysis was used to establish the discriminatory characteristics of each threshold.

resultsThe area under the curve, sensitivity, specificity, and positive and negative predictive values for the ability of each implant-specific threshold to distinguish between patients with and without ARMD were, respectively, 89.4% (95% confidence interval [CI] = 82.8% to 96.0%), 78.9%, 86.7%, 44.1%, and 96.9% for unilateral BHR; 89.2% (CI = 81.3% to 97.1%), 70.6%, 86.8%, 54.5%, and 93.0% for bilateral BHR; and 76.9% (CI = 63.9% to 90.0%), 65.0%, 85.4%, 24.5%, and 97.1% for unilateral Corail-Pinnacle implants. Using the implant-specific thresholds, we missed 20 patients with ARMD (2.8% of the patients in this series). We missed more patients with ARMD when we used the fixed thresholds proposed by regulatory authorities: 35 (4.9%) when we used the U.K. threshold of 7 μg/L for both cobalt and chromium (p = 0.0003), 21 (3.0%) when we used the U.S. threshold of 3 μg/L for both cobalt and chromium (p = 1.0), and 46 (6.5%) when we used the U.S. threshold of 10 μg/L for both cobalt and chromium (p < 0.0001).

conclusionsThis external multicenter validation study confirmed that patients with blood metal ion levels below new implant-specific thresholds have a low risk of ARMD after MoM hip arthroplasty. Using these implant-specific thresholds, we missed fewer patients with ARMD compared with when the thresholds currently proposed by regulatory authorities were used. We therefore recommend using implant-specific blood metal ion thresholds when managing patients who have undergone MoM hip arthroplasty. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

Indexed as

Arthroplasty, Replacement, HipAdultAgedAged, 80 and overChromiumCobaltFemaleForeign BodiesForeign-Body ReactionHip ProsthesisHumansMaleMetal-on-Metal Joint ProsthesesMiddle AgedPredictive Value of TestsProsthesis DesignChromiumCobalt

Identifiers

PMID28926382
PMCPMC5805279
OpenAlexW2757458382

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.