ArticleProceedings of the National Academy of Sciences of the United States of America2017
Transparent, conformable, active multielectrode array using organic electrochemical transistors.
Article in Proceedings of the National Academy of Sciences of the United States of America, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 62 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
62 citing papers in PubMed.
- High pressure transcranial focused ultrasound stimulation induces parameter-dependent cell-type specific effects.Microsystems & nanoengineering · 2026Review
- Active devices and systems for closed-loop neuromodulation.Microsystems & nanoengineering · 2026Review
- A conformable shape-stable self-healing polymer platform for continuous wireless arterial pulse monitoring.Nature communications · 2026Article
- Two-dimensional semiconductor-based active array for high-fidelity spatiotemporal monitoring of neural activities.Nature materials · 2026Article
- Organic Electrochemical Transistors in Tissue-Interfaced Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Hydrogel-elastomer-based conductive nanomembranes for soft bioelectronics.Nature nanotechnology · 2025Article
- A Photo-Patternable Solid-State Electrolyte for High-Performance, Miniaturized, and Implantable Organic Electrochemical Transistor-Based Circuits.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Addressing transconductance-bandwidth trade-off by three-dimensional electrolyte-surrounded organic electrochemical transistors.Science advances · 2025Article
- Emerging Electrolyte-Gated Transistors: Materials, Configuration and External Field Regulation.Materials (Basel, Switzerland) · 2025Review
- Additive Manufacturing of Organic Electrochemical Transistors: Methods, Device Architectures, and Emerging Applications.Small (Weinheim an der Bergstrasse, Germany) · 2025Review
- Materials and devices for high-density, high-throughput micro-electrocorticography arrays.Fundamental research · 2025Review
- In Situ Functionalization of Polar Polythiophene-Based Organic Electrochemical Transistor to Interface In Vitro Models.ACS applied materials & interfaces · 2024Article
- Integrated Microprism and Microelectrode Array for Simultaneous Electrophysiology and Two-Photon Imaging across All Cortical Layers.Advanced healthcare materials · 2024Article
- Optogenetic Brain-Computer Interfaces.Bioengineering (Basel, Switzerland) · 2024Review
- Organic Electrochemical Transistors for Biomarker Detections.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Coin-sized, fully integrated, and minimally invasive continuous glucose monitoring system based on organic electrochemical transistors.Science advances · 2024Article
- Fully bioresorbable hybrid opto-electronic neural implant system for simultaneous electrophysiological recording and optogenetic stimulation.Nature communications · 2024Article
- Monolithically integrated high-density vertical organic electrochemical transistor arrays and complementary circuits.Nature electronics · 2024Article
- Flexible switch matrix addressable electrode arrays with organic electrochemical transistor and pn diode technology.Nature communications · 2024Article
- SPIRAL: integrating and aligning spatially resolved transcriptomics data across different experiments, conditions, and technologies.Genome biology · 2023Article
2 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Mechanically flexible active multielectrode arrays (MEA) have been developed for local signal amplification and high spatial resolution. However, their opaqueness limited optical observation and light stimulation during use. Here, we show a transparent, ultraflexible, and active MEA, which consists of transparent organic electrochemical transistors (OECTs) and transparent Au grid wirings. The transparent OECT is made of Au grid electrodes and has shown comparable performance with OECTs with nontransparent electrodes/wirings. The transparent active MEA realizes the spatial mapping of electrocorticogram electrical signals from an optogenetic rat with 1-mm spacing and shows lower light artifacts than noise level. Our active MEA would open up the possibility of precise investigation of a neural network system with direct light stimulation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials