Evidence map›Paper›PMID 28921404›Full record

ArticleDysphagia2018

Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom.

Yoshiaki Morishima, Koichi Chida, Yoshikazu Muroya, Yoshiya Utsumi

Abstract read
PubMed Publisher
In one paragraph

Article in Dysphagia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Yoshiaki MorishimaDepartment of Radiology, Tohoku Medical and Pharmaceutical University Hospital, 1-12-1 Fukumuro, Miyagino-ku, Sendai, 983-8512, Japan. morishima@med.tohoku.ac.jp.
Koichi ChidaDepartment of Radiological Technology, Tohoku University School of Health Sciences, Sendai, 980-8575, Japan.
Yoshikazu MuroyaRehabilitation Center, Tohoku Medical and Pharmaceutical University Hospital, Sendai, 983-8512, Japan.
Yoshiya UtsumiRehabilitation Center, Tohoku Medical and Pharmaceutical University Hospital, Sendai, 983-8512, Japan.
Tohoku Medical and Pharmaceutical University Hospital · JPTohoku University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Interventional radiology procedures often involve lengthy exposure to fluoroscopy-derived radiation. We therefore devised a videofluoroscopic swallowing study (VFSS) procedure using a human phantom that proved to protect the patient and physician by reducing the radiation dose. We evaluated a new lead-shielding device and separately attached additional filters (1.0-, 2.0-, and 3.0-mm Al filters and a 0.5-mm Cu filter) during VFSS to reduce the patient's entrance skin dose (ESD). A monitor attached to the human phantom's neck measured the ESD. We also developed another lead shield (VFSS Shielding Box, 1.0-mm Pb equivalent) and tested its efficacy using the human phantom and an ionization chamber radiation survey meter with and without protection from scattered radiation at the physician's position on the phantom. We then measured the scattered radiation (at 90 and 150 cm above the floor) after combining the filters with the VFSS Shielding Box. With the additional filters, the ESD was reduced by 15.4-55.1%. With the VFSS Shielding Box alone, the scattered radiation was reduced by about 10% compared with the dose without additional shielding. With the VFSS Shielding Box and filters combined, the scattered radiation dose was reduced by a maximum of about 44% at the physician's position. Thus, the additional lead-shielding device effectively provided protection from scattered radiation during fluoroscopy. These results indicate that the combined VFSS Shielding Box and filters can effectively reduce the physician's and patient's radiation doses.

Indexed as

Radiation ProtectionDeglutitionFluoroscopyHumansOccupational ExposurePhantoms, ImagingRadiation DosageRadiation ExposureScattering, RadiationAdditional filterDeglutitionDeglutition disordersFluoroscopyOriginal lead shieldingScattered radiation protectionVideo recording

Identifiers

PMID28921404
OpenAlexW2754077465

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.