Evidence map›Paper›PMID 28917010›Full record

Observational studySurgical endoscopy2018

Differences of alternative methods of measuring abdominal wall hernia defect size: a prospective observational study.

Deepa V Cherla, Debbie F Lew, Richard J Escamilla, Julie L Holihan, Arun S Cherla, Juan Flores-Gonzalez, Tien C Ko, Lillian S Kao, Mike K Liang

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Surgical endoscopy, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Deepa V CherlaDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA. cherladv@gmail.com.
Debbie F LewDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Richard J EscamillaDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Julie L HolihanDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Arun S CherlaDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Juan Flores-GonzalezDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Tien C KoDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Lillian S KaoDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Mike K LiangDepartment of Surgery, Lyndon Baines Johnson Hospital, University of Texas Health Science Center at Houston, 5656 Kelley St, Houston, TX, 77026, USA.
Lyndon Baines Johnson Hospital · US

Funding

Center for Clinical and Translational Sciences (CCTS)KL2TR000370 · NCATS · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI MCPHERSON, DAVID D · 2012 to 2016
$4.3M
National Institutes of Health (US) UL1 TR000371NCATS NIH HHS KL2 TR000370
6 · The paper itself

Abstract

backgroundDespite the importance of defect size, there are no standardized recommendations on how to measure ventral hernias. Our aims were to determine (1) if any significant differences existed between various methods of measuring ventral hernias and (2) the effect of these methods of measurement on selection of mesh size.

methodA prospective study of all patients enrolled in a randomized trial assessing laparoscopic ventral hernia repair at a single institution from 3/2015 to 7/2016 was eligible for inclusion. Abdominal wall hernia defect size was determined by multiplying defect length and width obtained separately using each of five methods: radiographic (CT), intraoperative with abdomen desufflated, intraoperative with abdomen insufflated to 15 mmHg (intra-abdominal aspect), intraoperative with abdomen insufflated to 15 mmHg (extra-abdominal aspect), and clinical. The primary outcome was intraclass correlation between the five different methods of measurement for each patient. Secondary outcome was changes in mesh selection assuming a 5 cm overlap in each direction.

resultsFifty patients met inclusion criteria for assessment. The five different measurement methods had an intraclass correlation for each patient of 0.533 (95% CI 0.373-0.697) (weak correlation) for length; 0.737 (95% CI 0.613-0.844) (moderate correlation) for width; and 0.684 (95% CI 0.544-0.810) (moderate correlation) for area. Different types of measurements affected mesh selection in up to 56% of cases.

conclusionAmong five common methods of measuring abdominal wall hernia defect, sizes are only weakly to moderately correlated. Further studies are needed to determine which method results in optimally sized abdominal wall prostheses and superior ventral hernia repair.

Indexed as

Abdominal CavityAbdominal WallHernia, VentralHerniorrhaphyHumansProspective StudiesRandomized Controlled Trials as TopicSurgical MeshCorrelationHernia defectMeasurementsMeshVentral

Identifiers

PMID28917010
OpenAlexW2754776028

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.