Evidence map›Paper›PMID 28916952›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2018

Air-electron stream interactions during magnetic resonance IGRT : Skin irradiation outside the treatment field during accelerated partial breast irradiation.

Jong Min Park, Kyung Hwan Shin, Jung-In Kim, So-Yeon Park, Seung Hyuck Jeon, Noorie Choi, Jin Ho Kim, Hong-Gyun Wu

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Article
  2. Electron streaming dose measurements and calculations on a 1.5 T MR-Linac.Journal of applied clinical medical physics · 2024
    Article
  3. Review
  4. Adaptive radiotherapy for breast cancer.Clinical and translational radiation oncology · 2023
    Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Estimation of secondary cancer projected risk after partial breast irradiation at the 1.5 T MR-linac.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. MRI-Guided Radiation Therapy.Advances in oncology · 2021
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jong Min ParkDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).
Kyung Hwan ShinDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of). radiat@snu.ac.kr.
Jung-In KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).
So-Yeon ParkDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).
Seung Hyuck JeonDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).
Noorie ChoiDepartment of Radiation Oncology, Seoul National University College of Medicine, Seoul, Korea (Republic of).
Jin Ho KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).
Hong-Gyun WuDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Korea (Republic of).

Funding

National Research Foundation of Korea 2015R1C1A1A01054192
6 · The paper itself

Abstract

purposeTo investigate and to prevent irradiation outside the treatment field caused by an electron stream in the air generated by the magnetic field during magnetic resonance image-guided accelerated partial breast irradiation (APBI). MATERIALS AND

methodsIn all, 20 patients who received APBI with a magnetic resonance image-guided radiation therapy (MR-IGRT) system were prospectively studied. The prescription dose was 38.5 Gy in 10 fractions of 3.85 Gy and delivered with a tri-cobalt system (the ViewRay system). For each patient, primary plans were delivered for the first five fractions and modified plans with different gantry angles from those of the primary plan (in-treatment plans) were delivered for the remaining five fractions to reduce the skin dose. A 1 cm thick bolus was placed in front of the patient's jaw, ipsilateral shoulder, and arm to shield them from the electron stream. Radiochromic EBT3 films were attached to the front (towards the breast) and back (towards the head) of the bolus during treatment. Correlations between the measured values and the tumor locations, treatment times, and tumor sizes were investigated.

resultsFor a single fraction delivery, the average areas of the measured isodoses of 14% (0.54 Gy), 12% (0.46 Gy), and 10% (0.39 Gy) at the front of the boluses were as large as 3, 10.4, and 21.4 cm

conclusionDuring radiotherapy for breast cancer with an MR-IGRT system, the patient must be shielded from electron streams in the air generated by the interaction of the magnetic field with the beams of the three-cobalt treatment unit to avoid unwanted irradiation of the skin outside the treatment field.

Indexed as

AirAdultBreast NeoplasmsDose Fractionation, RadiationElectronsFemaleFilm DosimetryHumansMagnetic Resonance ImagingMammographyMiddle AgedPhantoms, ImagingProspective StudiesRadiation InjuriesRadiotherapy DosageRadiotherapy, Image-GuidedMagnetic fieldMagnetic resonance image-guided radiation therapyOrgans at riskOut-of-field exposureRadiation protection

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.