Evidence map›Paper›PMID 28901608›Full record

ArticleMedical physics2017

Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Xi Chen, Luo Ouyang, Hao Yan, Xun Jia, Bin Li, Qingwen Lyu, You Zhang, Jing Wang

Abstract read
In one paragraph

Article in Medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Adaptive proton therapy.Physics in medicine and biology · 2021
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xi ChenDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Luo OuyangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Hao YanCyber Medical Corporation, Xi'an, Shaanxi 710018, China.
Xun JiaDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Bin LiSchool of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, China.
Qingwen LyuZhujiang Hospital, Southern Medical University, Guangzhou, Guangdong 510515, China.
You ZhangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Jing WangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.

Funding

Next generation 4D-CBCT for lung cancer radiation therapyR01EB020366 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI WANG, JING · 2015 to 2018
$1.4M
NIBIB NIH HHS R01 EB020366
6 · The paper itself

Abstract

purposeX-ray scatter is a significant barrier to image quality improvements in cone-beam computed tomography (CBCT). A moving blocker-based strategy was previously proposed to simultaneously estimate scatter and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan. A blocker consisting of lead stripes is inserted between the X-ray source and the imaging object, and moves back and forth along the rotation axis during gantry rotation. While promising results were obtained in our previous studies, the geometric design and moving speed of the blocker were set empirically. The goal of this work is to optimize the geometry and speed of the moving block system.

methodsPerformance of the blocker was examined through Monte Carlo (MC) simulation and experimental studies with various geometry designs and moving speeds. All hypothetical designs employed an anthropomorphic pelvic phantom. The scatter estimation accuracy was quantified by using lead stripes ranging from 5 to 100 pixels on the detector plane. An iterative reconstruction based on total variation minimization was used to reconstruct CBCT images from unblocked projection data after scatter correction. The reconstructed image was evaluated under various combinations of lead strip width and interspace (ranging from 10 to 60 pixels) and different moving speed (ranging from 1 to 30 pixels per projection).

resultsMC simulation showed that the scatter estimation error varied from 0.8% to 5.8%. Phantom experiment showed that CT number error in the reconstructed CBCT images varied from 13 to 35. Highest reconstruction accuracy was achieved when the strip width was 20 pixels and interspace was 60 pixels and the moving speed was 15 pixels per projection.

conclusionsScatter estimation can be achieved in a large range of lead strip width and interspace combinations. The moving speed does not have a very strong effect on reconstruction result if it is above 5 pixels per projection. Geometry design of the blocker affected image reconstruction accuracy more. The optimal geometry of the blocker has a strip width of 20 pixels and an interspace three times the strip width, which means 25% detector is covered by the blocker, while the optimal moving speed is 15 pixels per projection.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedAlgorithmsArtifactsHumansPhantoms, ImagingScattering, Radiationcone-beam CTimaging artifactsmoving blockeroptimizationscatter correction

Identifiers

PMID28901608
PMCPMC5619659

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.