ReviewJournal of thoracic disease2017
BRS implantation in long lesions requiring device overlapping: myth or reality?
Review in Journal of thoracic disease, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Minimally overlapping technique of bioresorbable scaffolds in a porcine coronary artery model: proof-of-concept study.Scientific reports · 2025Article
- Clinical results of bioresorbable drug-eluting scaffolds in short and long coronary artery lesions using the PSP technique.BMC cardiovascular disorders · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dealing with bioresorbable vascular scaffolds (BVS) implantation in long lesions requiring device overlapping in this particular moment might seem a little provocative for several reasons. First, most studies testing BVS have focused on their safety and efficacy profile in simple patients with simple lesions. Second, ABSORB II did not meet its primary endpoint, while ABSORB III showed a higher rate of target vessel-myocardial infarction (TV-MI) at 2 years. Third, data on porcine model showed that overlapping zone has delayed but greater neointimal proliferation with consequent higher risk for scaffold thrombosis in the short-term and of in-scaffold restenosis in the long-term. Fourth, recently published data showed higher risk of TVF in patients treated with ≥60 mm BVS. Given all these premises, it may seem right to put aside this technology, while it may seem inappropriate to hypothesize the use of BVS in long lesions. The aim of the present review is precisely to critically review the available evidences regarding BVS with particular regard to overlapping BVS in order to understand whether this technology has a future per se and especially in long coronary lesions requiring overlap.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.