Evidence map›Paper›PMID 28894138›Full record

ArticleScientific reports2017

Mechanical bone growth stimulation by magnetic fibre networks obtained through a competent finite element technique.

Wolfram A Bosbach

Abstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Wolfram A BosbachUniversity of Cambridge, Engineering Department, Cambridge, CB2 1PZ, UK. wb248@cantab.net.ORCID 0000-0003-4182-3516

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fibre networks combined with a matrix material in their void phase make the design of novel and smart composite materials possible. Their application is of great interest in the field of advanced paper or as bioactive tissue engineering scaffolds. In the present study, we analyse the mechanical interaction between metallic fibre networks under magnetic actuation and a matrix material. Experimentally validated FE models are combined for that purpose in one joint simulation. High performance computing facilities are used. The resulting strain in the composite's matrix is not uniform across the sample volume. Instead we show that boundary conditions and proximity to the fibre structure strongly influence the local strain magnitude. An analytical model of local strain magnitude is derived. The strain magnitude of 0.001 which is of particular interest for bone growth stimulation is achievable by this assembly. In light of these findings, the investigated composite structure is suitable for creating and for regulating contactless a stress field which is to be imposed on the matrix material. Topics for future research will be the advanced modelling of the biological components and the potential medical utilisation.

Indexed as

Finite Element AnalysisMechanical PhenomenaOsteogenesisStress, MechanicalAlgorithmsHumansModels, Theoretical

Identifiers

PMID28894138
PMCPMC5593920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.