Evidence map›Paper›PMID 28883388›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2017

Retrospective Clinical Study of the Effects of T-Tube Placement for Bile Duct Stricture.

İbrahim Tayfun Şahiner, Murat Kendirci

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. A Novel Remote-Controlled Injection Device for T-Tube Cholangiography: A Feasibility Study in Canines.Medical science monitor : international medical journal of experimental and clinical research · 2019
    Article
  5. Article
  6. Financial Aspects of Bile Duct Injuries.Medical science monitor : international medical journal of experimental and clinical research · 2017
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

İbrahim Tayfun ŞahinerDepartment of Surgery, Hitit University School of Medicine, Erol Olçok Training and Research Hospital, Çorum, Turkey.
Murat KendirciDepartment of Surgery, Hitit University School of Medicine, Erol Olçok Training and Research Hospital, Çorum, Turkey.
Hitit Üniversitesi · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND T-tube placement in the common bile duct (CBD) is a surgical alternative to bile duct reconstruction in cholecystectomy for cholecysto-choledocholithiasis, or gallstones. The aim of this retrospective clinical study was to investigate the incidence of late complications of T-tube placement. MATERIAL AND METHODS Retrospective review identified 35 patients who had T-tube placement during cholecystectomy. Clinical data were collected on surgical indications, patient demographics, and clinical symptoms. Ultrasound (US) was used measure the diameter of the common bile duct (CBD), intrahepatic ducts, and presence or absence of stones in the CBD. Data from laboratory investigations included the aspartate aminotransferase-to-platelet ratio index (APRI), which was used as a non-invasive method to evaluate both cholestasis and liver fibrosis. RESULTS Of the 35 patients included in the study, 33 (94.3%) underwent open cholecystectomy, CBD exploration, and T-tube placement due to cholecysto-choledocholithiasis. The remaining two patients (5.7%) underwent primary CBD repair and T-tube placement secondary to CBD injury. The mean follow-up period after T-tube placement was 69 months. In patients with T-tube placement, the CBD diameters ranged from 4-21 mm, were normal in 20 patients (57.1%), dilated in 15 patients (42.9%), with the mean CBD diameter being 8.91±4.82 mm. No residual or recurrent CBD calculus and no clinical or laboratory evidence of cholangitis or cholestasis were found. CONCLUSIONS A retrospective clinical study at a single surgical center, showed that T-tube placement during open cholecystectomy and CBD exploration was a safe procedure that did not result in late complications.

Indexed as

Prostheses and ImplantsAdultCholecystectomy, LaparoscopicCholedocholithiasisCholedochostomyCholestasisCommon Bile DuctConstriction, PathologicFemaleGallstonesHumansIncidenceMaleMiddle AgedPostoperative ComplicationsRetrospective Studies

Identifiers

PMID28883388
PMCPMC5601390
OpenAlexW2750667756

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.