Evidence map›Paper›PMID 28883208›Full record

ArticleIndustrial health2018

Basic study of intratracheal instillation study of nanomaterials for the estimation of the hazards of nanomaterials.

Yasuo Morimoto, Hiroto Izumi, Yukiko Yoshiura, Yuri Fujisawa, Kazuhiro Yatera, Katsuhide Fujita, Junko Maru, Shigehisa Endoh, Kazumasa Honda

Open access · diamondAbstract read
In one paragraph

Article in Industrial health, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.1field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Molecular imaging and biology · 2025
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Yasuo MorimotoUniversity of Occupational and Environmental Health, Japan.
Hiroto IzumiUniversity of Occupational and Environmental Health, Japan.
Yukiko YoshiuraUniversity of Occupational and Environmental Health, Japan.
Yuri FujisawaUniversity of Occupational and Environmental Health, Japan.
Kazuhiro YateraUniversity of Occupational and Environmental Health, Japan.
Katsuhide FujitaNational Institute of Advanced Industrial Science and Technology, Japan.
Junko MaruNational Institute of Advanced Industrial Science and Technology, Japan.
Shigehisa EndohNational Institute of Advanced Industrial Science and Technology, Japan.
Kazumasa HondaNational Institute of Advanced Industrial Science and Technology, Japan.
University of Occupational and Environmental Health Japan · JPNational Institute of Advanced Industrial Science and Technology · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to examine the usefulness of intratracheal instillation of nanoparticles for the screening of the harmful effects of nanoparticles, we performed intratracheal instillation studies of nanomaterials on rats using different delivery devices and postures as a basic study. Multiwall carbon nanotubes (MWCNTs) with a geometric mean length and secondary diameter of 2.16 μm and 752 nm, respectively, were used as the nanomaterials. Male F344 rats were intratracheally exposed to 0.04 or 0.2 mg/rat of MWCNT, were dissected at 1 d and 3 d, and cell analyses of the bronchoalveolar lavage fluid (BALF) were analyzed. Two delivery devices were used for the intratracheal instillation of the MWCNTs: a gavage needle and a microsprayer aerolizer. Both induced neutrophil influx in the lung at 1 and 3 d, and there were no significant differences in neutrophil inflammation between the two delivery devices. The main distribution of pulmonary inflammation by both delivery devices was in the centrilobular spaces in the lung. Two postures were used: an angle of approximately 45 degrees and a standing posture on a board, both of which also induced pulmonary influx in BALF and pulmonary inflammation mainly in the centrilobular spaces, with no large difference in pulmonary inflammation between the two postures. Taken together, the differences in the delivery devices and postures of the rats in the intratracheal instillation did not affect the acute pulmonary toxicity of the nanomaterials.

Indexed as

AnimalsBronchoalveolar Lavage FluidLungMaleNanoparticlesNanotubes, CarbonNeutrophilsPneumoniaPostureRats, Inbred F344Nanotubes, CarbonAdministrationHarmful effectInflammationIntratracheal instillationNanomaterial

Identifiers

PMID28883208
PMCPMC5800863
OpenAlexW2752112473

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.