Evidence map›Paper›PMID 28877495›Full record

ArticleBiophysical journal2017

Wave Mechanics of the Vestibular Semicircular Canals.

Marta M Iversen, Richard D Rabbitt

Abstract readValidation Study
In one paragraph

Article in Biophysical journal, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Developing a Virtual Model of the Rhesus Macaque Inner Ear.Bioengineering (Basel, Switzerland) · 2024
    Article
  9. Article
  10. Article
  11. Differential Activation of Canal and Otolith Afferents by Acoustic Tone Bursts in Rats.Journal of the Association for Research in Otolaryngology : JARO · 2022
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Light Cupula: To Be Or Not to Be?Current medical science · 2020
    Review
  17. Article
  18. Biomechanics of Third Window Syndrome.Frontiers in neurology · 2020
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Marta M IversenDepartment of Bioengineering, University of Utah, Salt Lake City, Utah. Electronic address: marta.iversen@utah.edu.
Richard D RabbittDepartment of Bioengineering, University of Utah, Salt Lake City, Utah; Department of Otolaryngology, University of Utah, Salt Lake City, Utah; Marine Biological Laboratory, Woods Hole, Massachusetts.

Funding

Biophysics and Biomechanics of the Semicircular CanalsR01DC006685 · NIDCD · UNIVERSITY OF UTAH · PI RABBITT, RICHARD D · 2005 to 2022
$6.8M
Neural mechanisms of sound activation of vestibular systemR01DC012060 · NIDCD · UNIVERSITY OF MISSISSIPPI MED CTR · PI ZHU, HONG · 2012 to 2016
$1.9M
NIDCD NIH HHS R01 DC006685NIDCD NIH HHS R01 DC012060
6 · The paper itself

Abstract

The semicircular canals are biomechanical sensors responsible for detecting and encoding angular motion of the head in 3D space. Canal afferent neurons provide essential inputs to neural circuits responsible for representation of self-position/orientation in space, and to compensatory circuits including the vestibulo-ocular and vestibulo-collic reflex arcs. In this work we derive, to our knowledge, a new 1D mathematical model quantifying canal biomechanics based on the morphology, dynamics of the inner ear fluids, and membranous labyrinth deformability. The model takes the form of a dispersive wave equation and predicts canal responses to angular motion, sound, and mechanical stimulation. Numerical simulations were carried out for the morphology of the human lateral canal using known physical properties of the endolymph and perilymph in three diverse conditions: surgical plugging, rotation, and mechanical indentation. The model reproduces frequency-dependent attenuation and phase shift in cases of canal plugging. During rotation, duct deformability extends the frequency bandwidth and enhances the high frequency gain. Mechanical indentation of the membranous duct at high frequencies evokes traveling waves that move away from the location of indentation and at low frequencies compels endolymph displacement along the canal. These results demonstrate the importance of the conformal perilymph-filled bony labyrinth to pressure changes and to high frequency sound and vibration.

Indexed as

Models, BiologicalAnimalsBatrachoidiformesBiomechanical PhenomenaComputer SimulationHead MovementsHumansHydrodynamicsLinear ModelsMotionPhysical StimulationPressureRotationSemicircular CanalsSoundVibration

Identifiers

PMID28877495
PMCPMC5658742

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.