Evidence map›Paper›PMID 28877208›Full record

ArticlePloS one2017

Surveillance for falsified and substandard medicines in Africa and Asia by local organizations using the low-cost GPHF Minilab.

Albert Petersen, Nadja Held, Lutz Heide, Difäm-EPN Minilab Survey Group

Abstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
44citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

44 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Smartphone-Assisted Thin-Layer Chromatography for Rapid Quality Screening of Metformin.Advances in pharmacological and pharmaceutical sciences · 2025
    Article
  10. Article
  11. Quality of Essential Medicines from Different Sources in Enugu and Anambra, Nigeria.The American journal of tropical medicine and hygiene · 2024
    Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Albert PetersenDifäm - German Institute for Medical Mission, Tübingen, Germany.
Nadja HeldPharmaceutical Institute, Eberhard Karls-University Tübingen, Tübingen, Germany.
Lutz HeidePharmaceutical Institute, Eberhard Karls-University Tübingen, Tübingen, Germany.ORCID http://orcid.org/0000-0001-7809-7453
Difäm-EPN Minilab Survey Group

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSubstandard and falsified medical products present a serious threat to public health, especially in low- and middle-income countries. Their identification using pharmacopeial analysis is expensive and requires sophisticated equipment and highly trained personnel. Simple, low-cost technologies are required in addition to full pharmacopeial analysis in order to accomplish widespread routine surveillance for poor-quality medicines in low- and middle-income countries.

methodsTen faith-based drug supply organizations in seven countries of Africa and Asia were each equipped with a Minilab of the Global Pharma Health Fund (GPHF, Frankfurt, Germany), suitable for the analysis of about 85 different essential medicines by thin-layer chromatography. Each organization was asked to collect approximately 100 medicine samples from private local medicine outlets, especially from the informal sector. The medicine samples were tested locally according to the Minilab protocols. Medicines which failed Minilab testing were subjected to confirmatory analysis in a WHO-prequalified medicine quality control laboratory in Kenya.

resultsOut of 869 medicine samples, 21 were confirmed to be substandard or falsified medical products. Twelve did not contain the stated active pharmaceutical ingredient (API), six contained insufficient amounts of the API, and three showed insufficient dissolution of the API. The highest proportion of substandard and falsified medicines was found in Cameroon (7.1%), followed by the Democratic Republic of Congo (2.7%) and Nigeria (1.1%). Antimalarial medicines were most frequently found to be substandard or falsified (9.5% of all antimalarials). Thin-layer chromatography according to the Minilab protocols was found to be specific and reproducible in the identification of medicines which did not contain the stated API. Since only samples which failed Minilab testing were subjected to confirmatory testing using pharmacopeial methods, this study did not assess the sensitivity of the Minilab methodology in the detection of substandard medicines, and may underestimate the prevalence of poor-quality medicines.

conclusionsSurveillance for poor-quality medicines can be carried out by local organizations in low- and middle-income countries using a simple, low-cost technology. Such surveillance can identify an important subgroup of the circulating substandard and falsified medical products and can help to prevent them from causing harm in patients. A collaboration of the national drug regulatory authorities with faith-based organizations and other NGOs may therefore represent a promising strategy towards the Sustainable Development Goal of "ensuring access to quality medicines".

Indexed as

AfricaAsiaChromatography, Thin LayerCounterfeit DrugsLaboratoriesSurveys and QuestionnairesCounterfeit Drugs

Identifiers

PMID28877208
PMCPMC5587284

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.