Evidence map›Paper›PMID 28869276›Full record

SynthesisThe Cochrane database of systematic reviews2017

Amniocentesis and chorionic villus sampling for prenatal diagnosis.

Zarko Alfirevic, Kate Navaratnam, Faris Mujezinovic

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 80 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
80citing papers in PubMed, 3 pooled it
32.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

80 citing papers in PubMed, 3 syntheses or guidelines pooled it, 409 citations in OpenAlex.

  1. Pooled it
  2. Guideline
  3. Pooled it
  4. Trial
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Practice Recommendations for Genetic Testing of Ataxias.Annals of clinical and translational neurology · 2025
    Review
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Article

20 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Zarko AlfirevicDepartment of Women's and Children's Health, The University of Liverpool, First Floor, Liverpool Women's NHS Foundation Trust, Crown Street, Liverpool, UK, L8 7SS.
Kate Navaratnam
Faris Mujezinovic
Liverpool Womens NHS Foundation Trust · GBUniversity Clinical Centre Maribor · SIUniversity of Liverpool · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling (CVS), or fetal blood. A major disadvantage of second trimester amniocentesis is that the results are available relatively late in pregnancy (after 16 weeks' gestation). Earlier alternatives are chorionic villus sampling (CVS) and early amniocentesis, which can be performed in the first trimester of pregnancy.

objectivesThe objective of this review was to compare the safety and accuracy of all types of AC (i.e. early and late) and CVS (e.g. transabdominal, transcervical) for prenatal diagnosis. SEARCH

methodsWe searched the Cochrane Pregnancy and Childbirth Group's Trials Register (3 March 2017), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP; 3 March 2017), and reference lists of retrieved studies. SELECTION CRITERIA: All randomised trials comparing AC and CVS by either transabdominal or transcervical route. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. The quality of the evidence was assessed using the GRADE approach. MAIN

resultsWe included a total of 16 randomised studies, with a total of 33,555 women, 14 of which were deemed to be at low risk of bias. The number of women included in the trials ranged from 223 to 4606.Studies were categorized into six comparisons: 1. second trimester AC versus control; 2. early versus second trimester AC; 3. CVS versus second trimester AC; 4. CVS methods; 5. Early AC versus CVS; and 6. AC with or without ultrasound.One study compared second trimester AC with no AC (control) in a low risk population (women = 4606). Background pregnancy loss was around 2%. Second trimester AC compared to no testing increased total pregnancy loss by another 1%. The confidence intervals (CI) around this excess risk were relatively large (3.2% versus 2.3 %, average risk ratio (RR) 1.41, 95% CI 0.99 to 2.00; moderate-quality evidence). In the same study, spontaneous miscarriages were also higher (2.1% versus 1.3%; average RR 1.60, 95% CI 1.02 to 2.52; high-quality evidence). The number of congenital anomalies was similar in both groups (2.0% versus 2.2%, average RR 0.93, 95% CI 0.62 to 1.39; moderate-quality evidence).One study (women = 4334) found that early amniocentesis was not a safe early alternative compared to second trimester amniocentesis because of increased total pregnancy losses (7.6% versus 5.9%; average RR 1.29, 95% CI 1.03 to 1.61; high-quality evidence), spontaneous miscarriages (3.6% versus 2.5%, average RR 1.41, 95% CI 1.00 to 1.98; moderate-quality evidence), and a higher incidence of congential anomalies, including talipes (4.7% versus 2.7%; average RR 1.73, 95% CI 1.26 to 2.38; high-quality evidence).When pregnancy loss after CVS was compared with second trimester AC, there was a clinically significant heterogeneity in the size and direction of the effect depending on the technique used (transabdominal or transcervical), therefore, the results were not pooled. Only one study compared transabdominal CVS with second trimester AC (women = 2234). They found no clear difference between the two procedures in the total pregnancy loss (6.3% versus 7%; average RR 0.90, 95% CI 0.66 to 1.23, low-quality evidence), spontaneous miscarriages (3.0% versus 3.9%; average RR 0.77, 95% CI 0.49 to 1.21; low-quality evidence), and perinatal deaths (0.7% versus 0.6%; average RR 1.18, 95% CI 0.40 to 3.51; low-quality evidence). Transcervical CVS may carry a higher risk of pregnancy loss (14.5% versus 11.5%; average RR 1.40, 95% CI 1.09 to 1.81), but the results were quite heterogeneous.Five studies compared transabdominal and transcervical CVS (women = 7978). There were no clear differences between the two methods in pregnancy losses (average RR 1.16, 95% CI 0.81 to 1.65; very low-quality evidence), spontaneous miscarriages (average RR 1.68, 95% CI 0.79 to 3.58; very low-quality evidence), or anomalies (average RR 0.68, 95% CI 0.41 to 1.12; low-quality evidence). We downgraded the quality of the evidence to low due to heterogeneity between studies. Transcervical CVS may be more technically demanding than transabdominal CVS, with more failures to obtain sample (2.0% versus 1.1%; average RR 1.79, 95% CI 1.13 to 2.82, moderate-quality evidence).Overall, we found low-quality evidence for outcomes when early amniocentesis was compared to transabdominal CVS. Spontaneous miscarriage was the only outcome supported by moderate-quality evidence, resulting in more miscarriages after early AC compared with transabdominal CVS (2.3% versus 1.3%; average RR 1.73, 95% CI 1.15 to 2.60). There were no clear differences in pregnancy losses (average RR 1.15, 95% CI 0.86 to 1.54; low-quality evidence), or anomalies (average RR 1.14, 95% CI 0.57 to 2.30; very low-quality evidence).We found one study that examined AC with or without ultrasound, which evaluated a type of ultrasound-assisted procedure that is now considered obsolete. AUTHORS'

conclusionsSecond trimester amniocentesis increased the risk of pregnancy loss, but it was not possible to quantify this increase precisely from only one study, carried out more than 30 years ago.Early amniocentesis was not as safe as second trimester amniocentesis, illustrated by increased pregnancy loss and congenital anomalies (talipes). Transcervical chorionic villus sampling compared with second trimester amniocentesis may be associated with a higher risk of pregnancy loss, but results were quite heterogeneous.Diagnostic accuracy of different methods could not be assessed adequately because of incomplete karyotype data in most studies.

Indexed as

AmniocentesisChorionic Villi SamplingCongenital AbnormalitiesFemaleHumansPregnancyPregnancy Trimester, FirstPregnancy Trimester, SecondRandomized Controlled Trials as Topic

Identifiers

PMID28869276
PMCPMC6483702
OpenAlexW1898907433

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.