Evidence map›Paper›PMID 28865455›Full record

ArticleJournal of orthopaedic surgery and research2017

Comparison of conventional reconstruction plate versus direct metal laser sintering plate: an in vitro mechanical characteristics study.

Pusheng Xie, Hanbin Ouyang, Yuping Deng, Yang Yang, Jing Xu, Wenhua Huang

Abstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Experimental testing of fracture fixation plates: A review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pusheng XieGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China.
Hanbin OuyangGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China.
Yuping DengGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China.
Yang YangGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China.
Jing XuGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China.
Wenhua HuangGuangdong Provincial Key laboratory of Medical Biomechanics, Department of Anatomy, School of Basic Medicine Science, Southern Medical University, 1023 ShaTai Rd, Guangzhou, 510515, People's Republic of China. Orthobiomech@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdditive manufacturing (AM) technology has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. But the application of direct metal laser sintering (DMLS) bone plate is quite limited due to the indeterminate mechanical property. The purposes of this study were to characterize the biomechanical properties of the polished DMLS reconstruction plate and to compare these with the properties of commonly applied implants and to find whether the mechanical performance of DMLS plate meets the requirements for clinical application.

methodsIn this study, we fabricated two groups of plates by DMLS and computer numerical control (CNC) techniques. After that, we polished all samples and investigated their roughness, components, hardness, static bending, and torsional performance. Moreover, cyclic bending tests and fractographic analysis were conducted. Statistical comparisons of the group by means of monotonic test data were made, and a qualitative comparison was performed to assess failures in fatigue.

resultsWe found no differences in surface roughness or components after polishing, but the DMLS plate hardness is 7.42% (p < 0.01) greater than that of the CNC plates. Compared with the CNC plates, the DMLS plate static bending and torsional performance were significantly greater. In a dynamic test, the DMLS plates survived 10

conclusionsThese results indicate that the mechanical performances of the DMLS plate are stronger, and the strength under fatigue tests is sufficient. DMLS implant has great potential and may become a better choice for clinical use in the future. However, direct application of these AM instruments in the operating room requires further validation including animal and clinical experiment.

Indexed as

Bone PlatesLasersMaterials TestingMechanical PhenomenaCNCDMLSMechanical propertyReconstruction plateTi-6Al-4V

Identifiers

PMID28865455
PMCPMC5581440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked