Evidence map›Paper›PMID 28864847›Full record

ArticleMedical & biological engineering & computing2018

A monocentric centerline extraction method for ring-like blood vessels.

Fengjun Zhao, Feifei Sun, Yuqing Hou, Yanrong Chen, Dongmei Chen, Xin Cao, Huangjian Yi, Bin Wang, Xiaowei He, Jimin Liang

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fengjun ZhaoSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Feifei SunSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Yuqing HouSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Yanrong ChenSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Dongmei ChenCollege of Life Information Science and Instrument Engineering, Hangzhou Dianzi University, Hangzhou, Zhejiang, 310018, China.
Xin CaoSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Huangjian YiSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Bin WangSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China.
Xiaowei HeSchool of Information Sciences and Technology, Northwest University, Xi'an, Shaanxi, 710069, China. hexw@nwu.edu.cn.
Jimin LiangEngineering Research Center of Molecular and Neuro Imaging of Ministry of Education, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi, 710071, China. jimleung@mail.xidian.edu.cn.

Funding

National Natural Science Foundation of China (CN) 11571012National Natural Science Foundation of China (CN) 61601363
6 · The paper itself

Abstract

Centerline is generally used to measure topological and morphological parameters of blood vessels, which is pivotal for the quantitative analysis of vascular diseases. However, previous centerline extraction methods have two drawbacks on complex blood vessels, represented as the failure on ring-like structures and the existing of multi-voxel width. In this paper, we propose a monocentric centerline extraction method for ring-like blood vessels, which consists of three components. First, multiple centerlines are generated from the seed points that are chosen by randomly sprinkling points on blood vessel data. Second, multi-centerline fusion is used to repair the notches of centerlines on ring-like vessels, and the local maximum of distance from oundary is employed to remedy the missing centerline points. Finally, monocentric processing is devised to keep the vascular centerline with single voxel width. We compared the proposed method with Wan et al.'s method and topological thinning on five groups of data including synthesized vascular datasets and MR brain images. The result showed the proposed method performed better than the two contrast methods both by visual inspection and by quantitative assessment, which demonstrated the performance of the proposed method on ring-like blood vessels as well as the elimination of multi-voxel width points.

Indexed as

AlgorithmsBlood VesselsComputed Tomography AngiographyDatabases, FactualHumansImage Processing, Computer-AssistedMagnetic Resonance AngiographyBlood vesselsCenterline extractionInformation fusionMonocentric processing

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.