Evidence map›Paper›PMID 28860984›Full record

ArticleFrontiers in neuroinformatics2017

Early Seizure Detection by Applying Frequency-Based Algorithm Derived from the Principal Component Analysis.

Jiseon Lee, Junhee Park, Sejung Yang, Hani Kim, Yun Seo Choi, Hyeon Jin Kim, Hyang Woon Lee, Byung-Uk Lee

Abstract read
In one paragraph

Article in Frontiers in neuroinformatics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jiseon LeeDepartment of Electronics Engineering, Ewha Womans University College of EngineeringSeoul, South Korea.
Junhee ParkDepartment of Electronics Engineering, Ewha Womans University College of EngineeringSeoul, South Korea.
Sejung YangDepartment of Electronics Engineering, Ewha Womans University College of EngineeringSeoul, South Korea.
Hani KimDepartment of Neurology, Ewha Medical Research Institute, Ewha Womans University School of MedicineSeoul, South Korea.
Yun Seo ChoiDepartment of Neurology, Ewha Medical Research Institute, Ewha Womans University School of MedicineSeoul, South Korea.
Hyeon Jin KimDepartment of Neurology, Ewha Medical Research Institute, Ewha Womans University School of MedicineSeoul, South Korea.
Hyang Woon LeeDepartment of Neurology, Ewha Medical Research Institute, Ewha Womans University School of MedicineSeoul, South Korea.
Byung-Uk LeeDepartment of Electronics Engineering, Ewha Womans University College of EngineeringSeoul, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of automatic electrical stimulation in response to early seizure detection has been introduced as a new treatment for intractable epilepsy. For the effective application of this method as a successful treatment, improving the accuracy of the early seizure detection is crucial. In this paper, we proposed the application of a frequency-based algorithm derived from principal component analysis (PCA), and demonstrated improved efficacy for early seizure detection in a pilocarpine-induced epilepsy rat model. A total of 100 ictal electroencephalographs (EEG) during spontaneous recurrent seizures from 11 epileptic rats were finally included for the analysis. PCA was applied to the covariance matrix of a conventional EEG frequency band signal. Two PCA results were compared: one from the initial segment of seizures (5 sec of seizure onset) and the other from the whole segment of seizures. In order to compare the accuracy, we obtained the specific threshold satisfying the target performance from the training set, and compared the False Positive (FP), False Negative (FN), and Latency (Lat) of the PCA based feature derived from the initial segment of seizures to the other six features in the testing set. The PCA based feature derived from the initial segment of seizures performed significantly better than other features with a 1.40% FP, zero FN, and 0.14 s Lat. These results demonstrated that the proposed frequency-based feature from PCA that captures the characteristics of the initial phase of seizure was effective for early detection of seizures. Experiments with rat ictal EEGs showed an improved early seizure detection rate with PCA applied to the covariance of the initial 5 s segment of visual seizure onset instead of using the whole seizure segment or other conventional frequency bands.

Indexed as

early seizure detectionelectroencephalographyfrequency-based featureprincipal component analysisseizure onset

Identifiers

PMID28860984
PMCPMC5562675

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.