Evidence map›Paper›PMID 28858219›Full record

ArticleBiosensors2017

A Novel Impedance Biosensor for Measurement of Trans-Epithelial Resistance in Cells Cultured on Nanofiber Scaffolds.

Robert A Schramm, Matthew H Koslow, Deirdre A Nelson, Melinda Larsen, James Castracane

Abstract read
In one paragraph

Article in Biosensors, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Robert A SchrammColleges of Nanoscale Science and Engineering, SUNY Polytechnic Institute, 257 Fuller Road, Albany, NY 12203, USA. rschramm@sunypoly.edu.
Matthew H KoslowDepartment of Biological Sciences, University at Albany, State University of New York, 1400 Washington Avenue, Albany, NY 12222, USA. mkoslow@albany.edu.
Deirdre A NelsonDepartment of Biological Sciences, University at Albany, State University of New York, 1400 Washington Avenue, Albany, NY 12222, USA. dnelson@albany.edu.
Melinda LarsenDepartment of Biological Sciences, University at Albany, State University of New York, 1400 Washington Avenue, Albany, NY 12222, USA. mlarsen@albany.edu.
James CastracaneColleges of Nanoscale Science and Engineering, SUNY Polytechnic Institute, 257 Fuller Road, Albany, NY 12203, USA. jcastracane@sunypoly.edu.

Funding

Engineering Functional Salivary Glands Using Micropatterned ScaffoldsR01DE022467 · NIDCR · STATE UNIVERSITY OF NEW YORK AT ALBANY · PI CASTRACANE, JAMES, LARSEN, MELINDA · 2012 to 2016
$2.4M
Engineering Functioning Salivary Glands Using Micropatterned ScaffoldsR56DE022467 · NIDCR · STATE UNIVERSITY OF NEW YORK AT ALBANY · PI CASTRACANE, JAMES, LARSEN, MELINDA · 2017 to 2017
$653k
NIDCR NIH HHS R01 DE022467NIDCR NIH HHS R56 DE022467
6 · The paper itself

Abstract

Nanofibrous scaffolds provide high surface area for cell attachment, and resemble the structure of the collagen fibers which naturally occur in the basement membrane and extracellular matrix. A label free and non-destructive method of assessing the interaction of cell tissue and scaffolds aids in the ability to discern the effective quality and magnitude of any scaffold modifications. Impedance cell spectroscopy is a biosensing method that employs a functional approach to assessing the cell monolayer. The electrical impedance barrier function of a cell monolayer represents the level of restriction to diffusion of charged species between all adjacent cells across an entire contiguous cellular monolayer. The impedance signals from many individual paracellular pathways contribute to the bulk measurement of the whole monolayer barrier function. However, the scaffold substrate must be entirely porous in order to be used with electrochemical cell impedance spectroscopy (ECIS) and cells must be closely situated to the electrodes. For purposes of evaluating cell-scaffold constructs for tissue engineering, non-invasive evaluation of cell properties while seeded on scaffolds is critical. A Transwell-type assay makes a measurement across a semi-permeable membrane, using electrodes placed on opposing sides of the membrane immersed in fluid. It was found that by suspending a nanofiber scaffold across a Transwell aperture, it is possible to integrate a fully functional nanofiber tissue scaffold with the ECIS Transwell apparatus. Salivary epithelial cells were grown on the nanofiber scaffolds and tight junction formation was evaluated using ECIS measurements in parallel with immunostaining and confocal imaging. The trans-epithelial resistance increased coordinate with cell coverage, culminating with a cell monolayer, at which point the tight junction proteins assemble and strengthen, reaching the peak signal. These studies demonstrate that ECIS can be used to evaluate tight junction formation in cells grown on nanofiber scaffolds and on effects of scaffold conditions on cells, thus providing useful biological feedback to inform superior scaffold designs.

Indexed as

Electric ImpedanceAnimalsBiosensing TechniquesCell LineEpithelial CellsMiceNanostructuresTight JunctionsTissue Scaffoldsbarrier functionepithelial cellsimpedancenanofibersnon-destructive testingsalivary glandscaffoldtrans-epithelial electrical resistance

Identifiers

PMID28858219
PMCPMC5618041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked