ArticleBiomechanics and modeling in mechanobiology2018
Propagation of errors from skull kinematic measurements to finite element tissue responses.
Article in Biomechanics and modeling in mechanobiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.
- Head Impact Sensor Studies In Sports: A Systematic Review Of Exposure Confirmation Methods.Annals of biomedical engineering · 2020Pooled it
- Neuroimaging, wearable sensors, and blood-based biomarkers reveal hyperacute changes in the brain after sub-concussive impacts.Brain multiphysics · 2023Article
- Injury-Reduction Programs Containing Neuromuscular Neck Exercises and the Incidence of Soccer-Related Head and Neck Injuries.Journal of athletic training · 2023Article
- Analysis of relationship between loading condition and cranial cracking pattern using a three-dimensional finite element model.BMC musculoskeletal disorders · 2022Article
- Time Window of Head Impact Kinematics Measurement for Calculation of Brain Strain and Strain Rate in American Football.Annals of biomedical engineering · 2021Article
- Instantaneous Whole-Brain Strain Estimation in Dynamic Head Impact.Journal of neurotrauma · 2021Article
- Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football Impacts.Annals of biomedical engineering · 2020Article
- A network-based response feature matrix as a brain injury metric.Biomechanics and modeling in mechanobiology · 2020Article
- Concussion classification via deep learning using whole-brain white matter fiber strains.PloS one · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
Real-time quantification of head impacts using wearable sensors is an appealing approach to assess concussion risk. Traditionally, sensors were evaluated for accurately measuring peak resultant skull accelerations and velocities. With growing interest in utilizing model-estimated tissue responses for injury prediction, it is important to evaluate sensor accuracy in estimating tissue response as well. Here, we quantify how sensor kinematic measurement errors can propagate into tissue response errors. Using previous instrumented mouthguard validation datasets, we found that skull kinematic measurement errors in both magnitude and direction lead to errors in tissue response magnitude and distribution. For molar design instrumented mouthguards susceptible to mandible disturbances, 150-400% error in skull kinematic measurements resulted in 100% error in regional peak tissue response. With an improved incisor design mitigating mandible disturbances, errors in skull kinematics were reduced to <50%, and several tissue response errors were reduced to <10%. Applying 30[Formula: see text] rotations to reference kinematic signals to emulate sensor transformation errors yielded below 10% error in regional peak tissue response; however, up to 20% error was observed in peak tissue response for individual finite elements. These findings demonstrate that kinematic resultant errors result in regional peak tissue response errors, while kinematic directionality errors result in tissue response distribution errors. This highlights the need to account for both kinematic magnitude and direction errors and accurately determine transformations between sensors and the skull.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials