ArticlePractical laboratory medicine2017
Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.
Article in Practical laboratory medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Point-of-Care Bilirubin Testing in Neonates: Comparative Performance of Blood Gas Analysis and Transcutaneous Bilirubinometry.Healthcare (Basel, Switzerland) · 2026Article
- Measurement of bilirubin in cerebrospinal fluid using the oxidase method on automated chemistry system advia XPT.Practical laboratory medicine · 2025Article
- Spectral analysis with highly collimated mini-LEDs as light sources for quantitative detection of direct bilirubin.Discover nano · 2024Article
- Noninvasive direct bilirubin detection by spectral analysis of color images using a Mini-LED light source.Discover nano · 2023Article
- Using Blue Mini-LEDs as a Light Source Designed a Miniaturized Optomechanical Device for the Detection of Direct Bilirubin.Nanoscale research letters · 2022Article
- Relationship between serum indirect bilirubin levels and skeletal muscle mass in older male and female patients with type 2 diabetes.PloS one · 2022Article
- Frequency of icteric interference in clinical chemistry laboratory tests and causes of severe icterus.Practical laboratory medicine · 2021Article
- Newborns bilirubin concentration determined by different methods in relation to hematocrit and albumin level.Journal of medical biochemistry · 2020Article
- Systemic alterations induced by phospholipase AInternational journal of experimental pathology · 2018Article
- Using Focused Laboratory Management and Quality Improvement Projects to Enhance Resident Training and Foster Scholarship.Academic pathologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND
methodsRetrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR).
resultsRetrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods.
conclusionsVanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.