Evidence map›Paper›PMID 28852022›Full record

ArticleScientific reports2017

Multipoint Tissue Circulation Monitoring with a Flexible Optical Probe.

Yoko Tomioka, Shintaro Enomoto, Jian Gu, Akiko Kaneko, Itsuro Saito, Yusuke Inoue, Taeseong Woo, Isao Koshima, Kotaro Yoshimura, Takao Someya and 1 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Yoko TomiokaDepartment of Plastic Surgery, Graduate School of Medicine, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan. yoko1031prs@gmail.com.ORCID 0000-0003-2119-6404
Shintaro EnomotoDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Jian GuDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Akiko KanekoDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Itsuro SaitoDepartment of Biomedical Engineering, Graduate School of Medicine, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Yusuke InoueDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Taeseong WooDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Isao KoshimaDepartment of Plastic Surgery, Graduate School of Medicine, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Kotaro YoshimuraDepartment of Plastic Surgery, Jichi Medical University, Japan, Yakushiji 3311, Shimotsuke-City, Tochigi, 329-0498, Japan.ORCID 0000-0002-7152-5475
Takao SomeyaDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Masaki SekinoDepartment of Electrical Engineering and Information Systems, Graduate School of Engineering, University of Tokyo, Japan, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
The University of Tokyo · JPJichi Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Compromised circulation is a potential complication during the postoperative period following tissue transplantation. The use of a monitoring device allows physicians to detect compromised circulation immediately. Such monitoring devices need to be continuously usable, wearable, and area-detectable. However, existing devices fail to satisfy all of these requirements simultaneously. We developed a wearable, multipoint pulse wave-monitoring device. An array of reflective optical sensors implemented on a thin film substrate was used as a lightweight and flexible probe. As a model of tissue transplantation, an inguinal flap in a Wistar rat was dissected and freed from all subcutaneous tissue. By ligating the artery or vein, ischemia or congestion was induced in the tissue. In a human study, ischemia or congestion was induced in the palm by pressing the feeding artery or cutaneous vein, respectively. The amplitude of the pulse wave was evaluated using the power spectrum of Fourier transformed signals. Pulse wave amplitude significantly decreased under compromised circulation in both animal and human models. Moreover, we accomplished 1 week of continuous wireless monitoring in healthy subjects. These results demonstrated the potential utility of the developed device in postoperative blood-flow monitoring to improve the rescue rate of transplanted tissue.

Indexed as

Optical DevicesAnimalsBlood Flow VelocityDisease Models, AnimalHemodynamic MonitoringHumansHyperemiaIschemiaPulse Wave AnalysisRats, WistarTissue Transplantation

Identifiers

PMID28852022
PMCPMC5575279
OpenAlexW2750302904

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.