Evidence map›Paper›PMID 28851293›Full record

ArticleBMC infectious diseases2017

Precisão e confiabilidade de um teste imuno-cromatográfico rápido NS1 para diagnóstico DENV-1 no ponto de atendimento e no laboratório.

Verónica Elizabeth Mata, Sonia Regina Lambert Passos, Yara Hahr Marques Hökerberg, Guilherme Miguéis Berardinelli, Maria Angelica Borges Dos Santos, Levy Vilas Boas Fukuoka, Anna Carolina Fontoura Seixas Rangel Maciel, Cintia Damasceno Dos Santos Rodrigues, Aline da Silva Santos, Raquel de Vasconcellos Carvalhaes de Oliveira

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in BMC infectious diseases, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Verónica Elizabeth Mata, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil. veronica.mata@ini.fiocruz.br.
Sonia Regina Lambert Passos, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Yara Hahr Marques Hökerberg, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Guilherme Miguéis Berardinelli, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Maria Angelica Borges Dos Santos, Rua Leopoldo Bulhões 1480 sala 601, Rio de Janeiro, RJ, CEP 21040-361, Brazil.
Levy Vilas Boas Fukuoka, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Anna Carolina Fontoura Seixas Rangel Maciel, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Cintia Damasceno Dos Santos Rodrigues, Av. Brasil 4365, CEP 21040-360, Rio de Janeiro, RJ, Brasil.
Aline da Silva Santos, Av. Brasil 4365, CEP 21040-360, Rio de Janeiro, RJ, Brasil.
Raquel de Vasconcellos Carvalhaes de Oliveira, Av. Brasil 4036 sala 201 A, CEP 21040-361, Rio de Janeiro, RJ, Brasil.
Centro de Tecnologia Mineral · BRFundação Oswaldo Cruz · BRPetrobras (Brazil) · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic.

methodsCross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI).

resultsAt 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0-84.1) and specificity (Sp) was 87.0% (95% CI: 66.4-97.2). Sn in serum/laboratory was 82% (95% CI: 74.1-88.6) and Sp 100% (95% CI: 85.8-100). Positive likelihood ratio was 5.9 (95% CI: 2.0-17.0) for whole blood/POC and 19.8 (95% CI: 2.9-135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74-0.93) or different observers (k = 0.81, 95% CI: 0.72-0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%.

conclusionsNS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen.

trial registrationUTN U1111-1145-9451 .

Indexed as

AdolescentAdultAgedAged, 80 and overBrazilCross-Sectional StudiesDengueDengue VirusEnzyme-Linked Immunosorbent AssayFemaleHumansMaleMiddle AgedPoint-of-Care SystemsProspective StudiesReproducibility of ResultsNS1 protein, dengue-1 virusViral Nonstructural ProteinsDengueDiagnosisNS1Point-of-care systemsReproducibility of resultsSensitivity and specificity

Identifiers

PMID28851293
PMCPMC5576130
OpenAlexW3000311966

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked