Evidence map›Paper›PMID 28851105›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2018

Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

Matthew J Meagher, Rachna N Parwani, Amarjit S Virdi, Dale R Sumner

Open access · bronzeAbstract readValidation Study
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Comparative analysis of theJournal of periodontal & implant science · 2024
    Article
  3. The relative contribution of bone microarchitecture and matrix composition to implant fixation strength in rats.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2022
    Article
  4. Article
  5. Article
  6. Biomechanics of Implant Fixation in Osteoporotic Bone.Current osteoporosis reports · 2020
    Review
  7. Early changes in serum osteocalcin and body weight are predictive of implant fixation in a rat model of implant loosening.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020
    Article
  8. Implant surface alters compartmental-specific contributions to fixation strength in rats.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2020
    Article
  9. Article
  10. Article
  11. A multiscale analytical approach to evaluate osseointegration.Journal of materials science. Materials in medicine · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Matthew J MeagherDepartment of Cell & Molecular Medicine, Rush University Medical Center, 600 S. Paulina St., Suite 507, Chicago, Illinois, 60612.
Rachna N ParwaniDepartment of Cell & Molecular Medicine, Rush University Medical Center, 600 S. Paulina St., Suite 507, Chicago, Illinois, 60612.
Amarjit S VirdiDepartment of Cell & Molecular Medicine, Rush University Medical Center, 600 S. Paulina St., Suite 507, Chicago, Illinois, 60612.
Dale R SumnerDepartment of Cell & Molecular Medicine, Rush University Medical Center, 600 S. Paulina St., Suite 507, Chicago, Illinois, 60612.
Rush University Medical Center · USUniversity of Portsmouth · GB

Funding

Detection and Treatment of Peri-Implant OsteolysisR01AR066562 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI SUMNER, D RICK · 2015 to 2019
$1.7M
Very High Resolution Laboratory MicroCT ScannerS10RR027980 · NCRR · RUSH UNIVERSITY MEDICAL CENTER · PI SUMNER, D RICK · 2010 to 2010
$496k
NCRR NIH HHS S10 RR027980NIAMS NIH HHS R01 AR066562
6 · The paper itself

Abstract

Histology and backscatter scanning electron microscopy (bSEM) are the current gold standard methods for quantifying bone-implant contact (BIC), but are inherently destructive. Microcomputed tomography (μCT) is a non-destructive alternative, but attempts to validate μCT-based assessment of BIC in animal models have produced conflicting results. We previously showed in a rat model using a 1.5 mm diameter titanium implant that the extent of the metal-induced artefact precluded accurate measurement of bone sufficiently close to the interface to assess BIC. Recently introduced commercial laboratory μCT scanners have smaller voxels and improved imaging capabilities, possibly overcoming this limitation. The goals of the present study were to establish an approach for optimizing μCT imaging parameters and to validate μCT-based assessment of BIC. In an empirical parametric study using a 1.5 mm diameter titanium implant, we determined 90 kVp, 88 µA, 1.5 μm isotropic voxel size, 1600 projections/180°, and 750 ms integration time to be optimal. Using specimens from an in vivo rat experiment, we found significant correlations between bSEM and μCT for BIC with the manufacturer's automated analysis routine (r = 0.716, p = 0.003) or a line-intercept method (r = 0.797, p = 0.010). Thus, this newer generation scanner's improved imaging capability reduced the extent of the metal-induced artefact zone enough to permit assessment of BIC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:979-986, 2018.

Indexed as

Prostheses and ImplantsAnimalsBone and BonesTitaniumX-Ray MicrotomographyTitaniumbone-implant contactmetal artefactmicroCTosseointegration

Identifiers

PMID28851105
PMCPMC5832531
OpenAlexW2750968737

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.