Evidence map›Paper›PMID 28847499›Full record

ArticleUltrasound in medicine & biology2017

Combining Subharmonic and Ultraharmonic Modes for Intravascular Ultrasound Imaging: A Preliminary Evaluation.

Himanshu Shekhar, Jeffrey S Rowan, Marvin M Doyley

Abstract readTechnical Report
In one paragraph

Article in Ultrasound in medicine & biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Chirp-Coded Subharmonic Imaging With Volterra Filtering: Histotripsy Bubble Cloud Assessment In Vitro and Ex Vivo.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  2. Contrast-Enhanced Imaging of Histotripsy Bubble Clouds Using Chirp-Coded Excitation and Volterra Filtering.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
  3. 3D Harmonic and Subharmonic Imaging for Characterizing Breast Lesions: A Multi-Center Clinical Trial.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2022
    Article
  4. Review
  5. Histotripsy Bubble Cloud Contrast With Chirp-Coded Excitation in Preclinical Models.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  6. Article
  7. Article
  8. Validation of Ultrasound Super-Resolution Imaging of Vasa Vasorum in Rabbit Atherosclerotic Plaques.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Himanshu ShekharDepartment of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA. Electronic address: himanshu.shekhar@uc.edu.
Jeffrey S RowanDepartment of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA.
Marvin M DoyleyDepartment of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA.

Funding

IVUS Detection of Rupture Prone PlaquesR01HL088523 · NHLBI · UNIVERSITY OF ROCHESTER · PI DOYLEY, MARVIN M · 2009 to 2013
$1.9M
Howard Hughes Medical InstituteNHLBI NIH HHS R01 HL088523
6 · The paper itself

Abstract

Contrast-enhanced intra-vascular ultrasound (CE-IVUS) imaging could provide clinicians a valuable tool to assess cardiovascular risk and guide the choice of therapeutic strategies. In this technical note, we evaluated the feasibility of combining subharmonic and ultraharmonic imaging to improve the performance of CE-IVUS. Vessel phantoms perfused with phospholipid-shelled ultrasound contrast agents were visualized using subharmonic, ultraharmonic and combined CE-IVUS modes with commercial peripheral and coronary imaging catheters. Flow channels as small as 0.8 mm and 0.5 mm were imaged at 12-MHz and 30-MHz transmit frequencies, respectively. Subharmonic and ultraharmonic imaging modes achieved a contrast-to-tissue ratio (CTR) up to 18.1 ± 1.8 dB and 19.6 ± 1.9 dB at 12-MHz, and 8.8 ± 1.8 and 12.5 ± 1.1 dB at 30-MHz transmit frequencies, respectively. Combining these modes improved the CTR to 32.5 ± 3.0 dB and 25.0 ± 1.6 dB at 12-MHz and 30-MHz transmit frequencies. These results underscore the potential of combined-mode CE-IVUS imaging. Furthermore, the demonstration of this approach with commercial catheters may serve as a first step toward the clinical translation of CE-IVUS.

Indexed as

Contrast MediaPhantoms, ImagingSignal Processing, Computer-AssistedAcousticsCoronary VesselsFeasibility StudiesImage EnhancementPhospholipidsUltrasonography, InterventionalContrast MediaPhospholipidsIntravascular ultrasoundNon-linear imagingSubharmonic imagingUltraharmonic imagingUltrasound contrast agentsVasa vasorum

Identifiers

PMID28847499
PMCPMC5679122

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.