Evidence map›Paper›PMID 28846447›Full record

ArticleDiabetes technology & therapeutics2017

Stability of Commercially Available Glucagon Formulation for Dual-Hormone Artificial Pancreas Clinical Use.

Nadine Taleb, Adèle Coriati, Christian Khazzaka, Jonathan Bayonne, Virginie Messier, Rémi Rabasa-Lhoret

Open access · greenAbstract read
In one paragraph

Article in Diabetes technology & therapeutics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. A Light Activated Glucagon Trimer with Resistance to Fibrillation.ACS biomaterials science & engineering · 2021
    Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Evolving Pharmacotherapeutic Strategies for Type 1 Diabetes Mellitus.The journal of pediatric pharmacology and therapeutics : JPPT : the official journal of PPAG
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Nadine Taleb1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Adèle Coriati1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Christian Khazzaka1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Jonathan Bayonne1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Virginie Messier1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Rémi Rabasa-Lhoret1 Institut de recherches cliniques de Montréal , Montréal, Québec, Canada .
Montreal Clinical Research Institute · CADiabetes Canada · CA

Funding

Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and sensor-augmented pump therapy in outpatient settingsDP3DK106930 · NIDDK · CLINICAL RESEARCH INSTITUTE OF MONTREAL · PI RABASA-LHORET, REMI · 2015 to 2015
$2.5M
CIHRNIDDK NIH HHS DP3 DK106930
6 · The paper itself

Abstract

backgroundAvailable glucagon formulations are approved for immediate use after reconstitution for severe hypoglycemia emergency treatment. However, they are used in dual-hormone artificial pancreas (insulin and glucagon) studies through subcutaneous infusion pumps over 24 h. Chemical and physical stability of such glucagon use have not been reported in a comprehensive manner. MATERIALS AND

methodsRecombinant Glucagon DNA (Eli Lilly) was used. Compatibility and sterility of glucagon delivery through subcutaneous pump systems were verified. Glucagon degradation through liquid chromatography with tandem mass spectrometry (LC-MS/MS), fibrillation using intrinsic tryptophan fluorescence shift, and bioactivity through a cell-protein kinase A-based fluorescent bioassay were assessed over a range of different physical conditions (temperature, movement, and air bubbles).

resultsSubcutaneous infusion pump systems administered glucagon in sterile conditions and with comparable accuracy to insulin delivery; mean absolute relative difference of actual versus expected weights were 1.2% ± 1.1% for glucagon and 1.1% ± 0.5% for insulin (P = 0.9). In comparison to freshly reconstituted samples, glucagon analyzed through LC-MS/MS was intact at 93.0% ± 7.0% after 24 h (P = 0.42) and 83.04% ± 6.0% after 48 h (P = 0.02) of incubation in pumps at 32°C. Peak wavelengths for Trp fluorescence did not differ from samples exposed to air bubbles or movement whether incubated (in infusion sets for 24 h at 32°) immediately or 24- and 48-h poststorage at 4°C (P = 0.10, 0.70 and 0.80, respectively) and no significant differences in bioactivity (shifts in EC

conclusionAvailable glucagon formulations are chemically and physically stable, as well as compatible with delivery through subcutaneous infusion pumps over 24 h and can be used in long-term clinical trials.

Indexed as

Drug StabilityPancreas, ArtificialDiabetes Mellitus, Type 1GlucagonHumansHypoglycemic AgentsInsulinInsulin Infusion SystemsGlucagonHypoglycemic AgentsInsulinArtificial pancreasDiabetesGlucagon formulation

Identifiers

PMID28846447
PMCPMC5653137
OpenAlexW2747918114

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.