ArticleJournal of medical imaging (Bellingham, Wash.)2017

Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy.

Zhenyu Xiong, Sarath Vijayan, Stephen Rudin, Daniel R Bednarek

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Fluoroscopic Procedure-Room Scatter-Dose Reduction Using a Region-of-Interest (ROI) Attenuator.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  3. Eye-Lens Dose Reduction using Region of Interest (ROI) Attenuators in Neuroimaging.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Investigation of organ dose variation with adult head size and pediatric age for neuro-interventional projections.Proceedings of SPIE--the International Society for Optical Engineering · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zhenyu XiongUniversity at Buffalo, Medical Physics Program, Buffalo, New York, United States.
Sarath VijayanUniversity at Buffalo, Medical Physics Program, Buffalo, New York, United States.
Stephen RudinUniversity at Buffalo, Medical Physics Program, Buffalo, New York, United States.
Daniel R BednarekUniversity at Buffalo, Medical Physics Program, Buffalo, New York, United States.

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
NIBIB NIH HHS R01 EB002873
6 · The paper itself

Abstract

In some medical-imaging procedures using cone-beam CT (CBCT) and fluoroscopy, only the center of the field of view (FOV) may be needed to be visualized with optimal image quality. To reduce the dose to the patient while maintaining visualization of the entire FOV, a Cu attenuator with a circular aperture for the region of interest (ROI) is used. The potential organ and effective dose reductions of ROI imaging when applied to CBCT and interventional fluoroscopic procedures were determined using EGSnrc Monte Carlo code. The Monte Carlo model was first validated by comparing the surface dose distribution in a solid-water block phantom with measurement by Gafchromic film. The dependence of dose reduction on the ROI attenuator thickness, the opening size of the ROI, the axial beam position, and the location of the different organs for both neuro and thoracic imaging was evaluated. The results showed a reduction in most organ doses of 45% to 70% and in effective dose of 46% to 66% compared to the dose in a CBCT scan and in an interventional procedure without the ROI attenuator. This work provides evidence of a substantial reduction of organ and effective doses when using an ROI attenuator during CBCT and fluoroscopic procedures.

Indexed as

cone-beam CTdose reductionEGSnrcinterventional fluoroscopy procedureMonte Carloregion-of-interest imaging

Identifiers

PMID28840169
PMCPMC5566265

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.