Evidence map›Paper›PMID 28836122›Full record

ArticleJournal of the American Society for Mass Spectrometry2018

Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit.

Yuan Tian, Trevor K Decker, Joshua S McClellan, Linsey Bennett, Ailin Li, Abraham De la Cruz, Derek Andrews, Stephen A Lammert, Aaron R Hawkins, Daniel E Austin

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. A Microscale Planar Linear Ion Trap Mass Spectrometer.Journal of the American Society for Mass Spectrometry · 2019
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Yuan TianDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA.
Trevor K DeckerDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA.
Joshua S McClellanDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA.
Linsey BennettDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA.
Ailin LiDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA.
Abraham De la CruzDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA.
Derek AndrewsDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA.
Stephen A LammertPerkinElmer, American Fork, UT, 84003, USA.
Aaron R HawkinsDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA.
Daniel E AustinDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA. austin@chem.byu.edu.
Brigham Young University · USPerkinElmer (United States) · US

Funding

National Science Foundation 1404886
6 · The paper itself

Abstract

We present a new two-plate linear ion trap mass spectrometer that overcomes both performance-based and miniaturization-related issues with prior designs. Borosilicate glass substrates are patterned with aluminum electrodes on one side and wire-bonded to printed circuit boards. Ions are trapped in the space between two such plates. Tapered ejection slits in each glass plate eliminate issues with charge build-up within the ejection slit and with blocking of ions that are ejected at off-nominal angles. The tapered slit allows miniaturization of the trap features (electrode size, slit width) needed for further reduction of trap size while allowing the use of substrates that are still thick enough to provide ruggedness during handling, assembly, and in-field applications. Plate spacing was optimized during operation using a motorized translation stage. A scan rate of 2300 Th/s with a sample mixture of toluene and deuterated toluene (D8) and xylenes (a mixture of o-, m-, p-) showed narrowest peak widths of 0.33 Th (FWHM). Graphical Abstract ᅟ.

Indexed as

Linear ion trap (LIT)MicrofabricationMiniaturizationPlate spacingResolutionScan rate

Identifiers

PMID28836122
OpenAlexW2749264090

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.