Evidence map›Paper›PMID 28835730›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2016

Design and characterization of a low profile NaI(Tl) gamma camera for dedicated molecular breast tomosynthesis.

Andrew M Polemi, Justin Niestroy, Alexander Stolin, Gangadhar Jaliparthi, Randy Wojcik, Stan Majewski, Mark B Williams

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 78% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Andrew M PolemiDept. of Biomedical Engineering, University of Virginia, 415 Lane Road, Charlottesville, VA USA 22908.
Justin NiestroyDept. of Physics, University of Virginia, 382 McCormick Rd., Charlottesville, VA USA 22908.
Alexander StolinDept. of Radiology, West Virginia University, P.O. Box 9100, Morgantown, WV USA 26506.
Gangadhar JaliparthiDept. of Radiology, West Virginia University, P.O. Box 9100, Morgantown, WV USA 26506.
Randy WojcikRay Visions, Inc., Yorktown, VA USA 23693.
Stan MajewskiDept. of Radiology and Medical Imaging, University of Virginia, 480 Ray C Hunt Drive, Charlottesville, VA USA 22908.
Mark B WilliamsDept. of Biomedical Engineering, University of Virginia, 415 Lane Road, Charlottesville, VA USA 22908.
University of Virginia · USWest Virginia University · US

Funding

Integrated three dimensional anatomic and molecular breast imagingR01CA149130 · NCI · UNIVERSITY OF VIRGINIA · PI HARVEY, JENNIFER A, REHM, PATRICE · 2011 to 2013
$1.0M
NCI NIH HHS R01 CA149130
6 · The paper itself

Abstract

A new low profile gamma camera is being developed for use in a dual modality (x-ray transmission and gamma-ray emission) tomosynthesis system. Compared to the system's current gamma camera, the new camera has a larger field of view (~20×25 cm) to better match the system's x-ray detector (~23×29 cm), and is thinner (7.3 cm instead of 10.3 cm) permitting easier camera positioning near the top surface of the breast. It contains a pixelated NaI(Tl) array with a crystal pitch of 2.2 mm, which is optically coupled to a 4×5 array of Hamamatsu H8500C position sensitive photomultiplier tubes (PSPMTs). The manufacturer-provided connector board of each PSPMT was replaced with a custom designed board that a) reduces the 64 channel readout of the 8×8 electrode anode of the H8500C to 16 channels (8X and 8Y), b) performs gain non-uniformity correction, and c) reduces the height of the PSPMT-base assembly, 37.7 mm to 27.87 mm. The X and Y outputs of each module are connected in a lattice framework, and at two edges of this lattice, the X and Y outputs (32Y by 40X) are coupled to an amplifier/output board whose signals are fed via shielded ribbon cables to external ADCs. The camera uses parallel hole collimation. We describe the measured camera imaging performance, including intrinsic and extrinsic spatial resolution, detection sensitivity, uniformity of response, energy resolution for 140 keV gamma rays, and geometric linearity.

Indexed as

breast imaginggamma cameranuclear medicine

Identifiers

PMID28835730
PMCPMC5565202
OpenAlexW2529815428

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.