ArticleBMC medical imaging2017
Cardiovascular magnetic resonance feature tracking in small animals - a preliminary study on reproducibility and sample size calculation.
Article in BMC medical imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Guidelines for measuring cardiac physiology in mice.American journal of physiology. Heart and circulatory physiology · 2018Guideline
- Effect of comprehensive initial training on the variability of left ventricular measures using fast-SENC cardiac magnetic resonance imaging.Scientific reports · 2019Trial
- Left ventricle strain and T1 mapping evaluation in a mouse model with myocardial infarction.Scientific reports · 2025Article
- Cardiac Phase-Resolved TBiomedicines · 2025Article
- Post-Myocardial Infarction Remodeling and Hyperkinetic Remote Myocardium in Sheep Measured by Cardiac MRI Feature Tracking.Journal of magnetic resonance imaging : JMRI · 2025Article
- Reliability of left ventricular hemodynamic forces derived from feature-tracking cardiac magnetic resonance.PloS one · 2024Article
- Cardiovascular magnetic resonance imaging for sequential assessment of cardiac fibrosis in mice: technical advancements and reverse translation.American journal of physiology. Heart and circulatory physiology · 2024Review
- Application of Magnetic Resonance Strain Analysis Using Feature Tracking in a Myocardial Infarction Model.Tomography (Ann Arbor, Mich.) · 2023Article
- Low-dose dobutamine cardiovascular magnetic resonance segmental strain study of early phase of intramyocardial hemorrhage rats.BMC medical imaging · 2021Article
- Pulmonary arterial banding in mice may be a suitable model for studies on ventricular mechanics in pediatric pulmonary arterial hypertension.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021Article
- Quantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals.BioMed research international · 2021Article
- Cardiovascular magnetic resonance feature tracking in pigs: a reproducibility and sample size calculation study.The international journal of cardiovascular imaging · 2020Article
- Serelaxin Improves Regional Myocardial Function in Experimental Heart Failure: An In Vivo Cardiac Magnetic Resonance Study.Journal of the American Heart Association · 2020Article
- Correlation between left ventricular myocardial strain and left ventricular geometry in healthy adults: a cardiovascular magnetic resonance-feature tracking study.The international journal of cardiovascular imaging · 2019Article
- Evaluation of a commercial multi-dimensional echocardiography technique for ventricular volumetry in small animals.Cardiovascular ultrasound · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCardiovascular magnetic resonance feature tracking (CMR-FT) is a novel tissue tracking technique developed for noninvasive assessment of myocardial motion and deformation. This preliminary study aimed to evaluate the observer's reproducibility of CMR-FT in a small animal (mouse) model and define sample size calculation for future trials.
methodsSix C57BL/6 J mice were selected from the ongoing experimental mouse model onsite and underwent CMR with a 3 Tesla small animal MRI scanner. Myocardial deformation was analyzed using dedicated software (TomTec, Germany) by two observers. Left ventricular (LV) longitudinal, circumferential and radial strain (Ell
resultsIn general, Ecc
conclusionsThis pilot study demonstrates good to excellent inter- and intra-observer reproducibility of CMR-FT technique in small animal model. The most reproducible measures are global circumferential and global longitudinal strain, whereas reproducibility of radial strain is weak. Furthermore, sample size calculation demonstrates that a small number of animals could be sufficient for future trials.