Evidence map›Paper›PMID 28833440›Full record

ArticleMagnetic resonance in medicine2018

Magnetization-prepared shells trajectory with automated gradient waveform design.

Yunhong Shu, Shengzhen Tao, Joshua D Trzasko, John Huston, Paul T Weavers, Matt A Bernstein

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Partial fourier shells trajectory for non-cartesian MRI.Physics in medicine and biology · 2019
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yunhong ShuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shengzhen TaoDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-3019-3491
Joshua D TrzaskoDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
John HustonDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Paul T WeaversDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Matt A BernsteinDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.ORCID 0000-0003-3770-0441

Funding

High Performance, Highly Deployable Head-Only MRI ScannerR01EB010065 · NIBIB · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2010 to 2015
$5.5M
EXTRAMURAL RES FACIL IMPROVEMENT PROG: POLYCYSTIC KIDNEY DISEASE, RENAL STUDIES,C06RR018898 · NCRR · MAYO CLINIC · PI BURNETT, JOHN C · 2004 to 2004
$2.3M
NCRR NIH HHS C06 RR018898NIBIB NIH HHS R01 EB010065
6 · The paper itself

Abstract

purposeTo develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast.

methodsAfter reviewing the shells k-space trajectory, a novel, fully automated trajectory design is developed that allows for gradient waveforms to be automatically generated for specified acquisition parameters. Designs for two types of shells are introduced, including fully sampled and undersampled/accelerated shells. Using those designs, an MP-Shells acquisition is developed by adjusting the acquisition order of shells interleaves to synchronize the center of k-space sampling with the peak of desired gray-to-white matter contrast. The feasibility of the proposed design and MP-Shells is demonstrated using simulation, phantom, and volunteer subject experiments, and the performance of MP-Shells is compared with a clinical Cartesian magnetization-prepared rapid gradient echo acquisition.

resultsInitial experiments show that MP-Shells produces excellent image quality with higher data acquisition efficiency and improved gray-to-white matter contrast-to-noise ratio (by 36%) compared with the conventional Cartesian magnetization-prepared rapid gradient echo acquisition.

conclusionWe demonstrated the feasibility of a three-dimensional MP-Shells acquisition and an automated trajectory design to achieve an efficient acquisition with improved gray-to-white matter contrast. Magn Reson Med 79:2024-2035, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Indexed as

Magnetic Resonance ImagingMagneticsAlgorithmsAutomationBrainContrast MediaGray MatterHealthy VolunteersHumansImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedImaging, Three-DimensionalPhantoms, ImagingSoftwareWhite MatterContrast Mediamagnetization preparednon-Cartesian MRIparallel imagingshells trajectory

Identifiers

PMID28833440
PMCPMC5811388

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.