Evidence map›Paper›PMID 28830467›Full record

ArticleBMC cancer2017

BiClamp® vessel-sealing device for open hepatic resection of malignant and benign liver tumours: a single-institution experience.

Yi-Jun Zhao, Da-Chen Zhou, Fu-Bao Liu, Hong-Chuan Zhao, Guo-Bin Wang, Xiao-Ping Geng

Abstract read
In one paragraph

Article in BMC cancer, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yi-Jun ZhaoDepartment of Hepatopancreatobiliary Surgery II, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui Province, 230022, China.
Da-Chen ZhouDepartment of Surgery, The Second Affiliated Hospital of Anhui Medical University, No. 678 Furong Road, Hefei, Anhui Province, 230601, China.
Fu-Bao LiuDepartment of Hepatopancreatobiliary Surgery II, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui Province, 230022, China.
Hong-Chuan ZhaoDepartment of Hepatopancreatobiliary Surgery II, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui Province, 230022, China.
Guo-Bin WangDepartment of Hepatopancreatobiliary Surgery II, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui Province, 230022, China.
Xiao-Ping GengDepartment of Hepatopancreatobiliary Surgery II, the First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui Province, 230022, China. xp_geng@163.net.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntraoperative blood loss during hepatectomy worsens prognosis, and various tools have been used to improve perioperative safety and feasibility. We aimed to retrospectively evaluate the feasibility and safety of the BiClamp® device for open liver resection.

methodsWe included 84 patients undergoing liver resection from a single centre, with all patients operated by the same surgical group. All hepatectomies were performed using BiClamp® (Erbe Elektromedizin GmbH, Tubingen, Germany), an electrosurgical device that simultaneously transects liver parenchyma and seals vessels <7 mm in diameter. We collected data on intraoperative blood loss, resection time, and perioperative complications, comparing cirrhotic and non-cirrhotic patients.

resultsThe 84 patients enrolled in this study included 56 cirrhotic and 28 non-cirrhotic patients. All patients underwent hepatectomy (30 major and 54 minor hepatectomies) using the BiClamp®, exclusively, and 54 patients required inflow occlusion (Pringle manoeuvre). Overall intraoperative blood loss (mean ± standard deviation) was 523.5 ± 558.6 ml, liver parenchymal transection time was 36.3 ± 16.5 min (range, 13-80 min), and the mean parenchymal transection speed was 3.0 ± 1.9 cm

conclusionsThe reusable BiClamp® vessel-sealing device allows for safe and feasible major and minor hepatectomy, even in patients with cirrhotic liver.

trial registrationThis trial was retrospectively registered and the detail information was as followed. Registration number: ChiCTR-ORC-17011873 (Chinese Clinical Trial Registry). Registration Date: 2017-07-05.

Indexed as

AdultBlood Loss, SurgicalElectrosurgeryFemaleHepatectomyHumansLiver NeoplasmsMaleMiddle AgedMorbidityMortalityNeoplasm MetastasisNeoplasm StagingOperative TimeTreatment OutcomeTumor BurdenBiClamp®HepatectomyIntraoperative blood lossVessel sealing

Identifiers

PMID28830467
PMCPMC5568315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.