Evidence map›Paper›PMID 28830195›Full record

ArticleThe British journal of radiology2017

Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

Elisa Almeida Sathler Bretas, Ulysses S Torres, Lucas Rios Torres, Daniel Bekhor, Celso Fernando Saito Filho, Douglas Jorge Racy, Lorenzo Faggioni, Giuseppe D'Ippolito

Abstract readComparative Study
In one paragraph

Article in The British journal of radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Elisa Almeida Sathler Bretas1 Department of Imaging, Universidade Federal de São Paulo, São Paulo, Brazil.
Ulysses S Torres2 Department of Radiology, Grupo Fleury, São Paulo, Brazil.
Lucas Rios Torres2 Department of Radiology, Grupo Fleury, São Paulo, Brazil.
Daniel Bekhor1 Department of Imaging, Universidade Federal de São Paulo, São Paulo, Brazil.
Celso Fernando Saito Filho1 Department of Imaging, Universidade Federal de São Paulo, São Paulo, Brazil.
Douglas Jorge Racy3 Department of Imaging, Hospital Beneficência Portuguesa, São Paulo, Brazil.
Lorenzo Faggioni4 Department of Diagnostic and Interventional Radiology, University Hospital of Pisa, Pisa, Italy.
Giuseppe D'Ippolito1 Department of Imaging, Universidade Federal de São Paulo, São Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages.

methodsThis retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics.

resultsInter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters.

conclusionAt best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

Indexed as

HemodynamicsSoftwareTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansLiverMaleMiddle AgedObserver VariationPerfusion ImagingReproducibility of ResultsRetrospective StudiesYoung Adult

Identifiers

PMID28830195
PMCPMC5853353

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.