Evidence map›Paper›PMID 28827905›Full record

ArticleThe Indian journal of surgery2017

Clinical Utility of Tc-99m MIBI SPECT/CT for Preoperative Localization of Parathyroid Lesions.

Zeynep Gozde Ozkan, Seher Nilgun Unal, Serkan Kuyumcu, Yasemin Sanli, Mehmet Fatih Gecer, Beyza Ozcinar, Yasemin Senyurek Giles, Yesim Erbil

Open access · bronzeAbstract read
In one paragraph

Article in The Indian journal of surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. European journal of nuclear medicine and molecular imaging · 2024
    Article
  3. Article
  4. Two Different Causes of Paediatric Hypercalcaemia.Sultan Qaboos University medical journal · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Zeynep Gozde OzkanIstanbul Medical Faculty, Nuclear Medicine Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Seher Nilgun UnalIstanbul Medical Faculty, Nuclear Medicine Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Serkan KuyumcuIstanbul Medical Faculty, Nuclear Medicine Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Yasemin SanliIstanbul Medical Faculty, Nuclear Medicine Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Mehmet Fatih GecerIstanbul Medical Faculty, Nuclear Medicine Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Beyza OzcinarIstanbul Medical Faculty, General Surgery Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Yasemin Senyurek GilesIstanbul Medical Faculty, General Surgery Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Yesim ErbilIstanbul Medical Faculty, General Surgery Department, Istanbul University, Millet Cad, 34390 Capa-Fatih, Istanbul Turkey.
Istanbul University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We aimed to demonstrate the role of SPECT/CT in preoperative localization of parathyroid lesions in patients with hyperparathyroidism who had technetium-99m (Tc-99m) methoxyisobutylisonitrile (MIBI) dual-phase parathyroid scintigraphy. We evaluated retrospectively the scintigraphic data of 103 patients who had parathyroidectomy after Tc-99m MIBI dual-phase parathyroid scintigraphy with SPECT/CT. The planar and SPECT/CT images were evaluated separately to determine their efficacy in localizing parathyroid lesions. These results were then compared with surgical data. There were 84 female and 19 male patients whose mean age was 54 ± 12 years. A total of 115 parathyroid lesions in 103 patients were resected during operations. In 87 patients, with both planar and SPECT/CT images, a total of 100 lesions could be detected correctly. In 11 patients, only SPECT/CT images could show 13 subcentimetric lesions. In three patients, three lesions were evaluated as parathyroid lesions both with planar and SPECT/CT images, but according to histopathologic evaluation, they came out to be nonparathyroidal lesions. In two patients, two parathyroid lesions could not be detected preoperatively neither with planar nor with SPECT/CT images. The lesion-based sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 87 %, 99 %, 97.1 %, 95.3 %, and 95.8 % for planar images and 98.3 %, 99 %, 97.4 %, 99.4 %, and 98.8 % for SPECT/CT images, respectively. Tc-99m MIBI parathyroid scintigraphy should be a diagnostic modality of choice in preoperative evaluation of patients with hyperparathyroidism. SPECT/CT has an incremental value both in demonstrating subcentimetric lesions and in accurately localizing lesions anatomically.

Indexed as

HyperparathyroidismParathyroid scintigraphySPECT/CTTc-99m MIBI

Identifiers

PMID28827905
PMCPMC5549043
OpenAlexW2347043793

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.