Evidence map›Paper›PMID 28823976›Full record

ArticleBiosensors & bioelectronics2018

A low cost mobile phone dark-field microscope for nanoparticle-based quantitative studies.

Dali Sun, Tony Y Hu

Abstract read
In one paragraph

Article in Biosensors & bioelectronics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 34 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. A review on low-cost microscopes for Open Science.Microscopy research and technique · 2022
    Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Dali SunSchool of Biological and Health Systems Engineering, Virginia G. Piper Biodesign Center for Personalized Diagnostics, The Biodesign Institute, Arizona State University, 727 E. Tyler St. B 130-B, Tempe, AZ 85287, United States.
Tony Y HuSchool of Biological and Health Systems Engineering, Virginia G. Piper Biodesign Center for Personalized Diagnostics, The Biodesign Institute, Arizona State University, 727 E. Tyler St. B 130-B, Tempe, AZ 85287, United States. Electronic address: tyhu@asu.edu.
Arizona State University · US

Funding

Direct quantitation of the circulating Mtb-peptidome for pediatric TB managementR01HD090927 · NICHD · TULANE UNIVERSITY OF LOUISIANA · PI Christopher J Lyon, Charles DeBeaux Mitchell · 2017 to 2026
$4.5M
Quantification of Circulating Antigens for Pediatric TB Diagnosis andTreatment MonitoringR01AI122932 · NIAID · METHODIST HOSPITAL RESEARCH INSTITUTE · PI HU, TONY Y. · 2016 to 2019
$1.8M
Real-time Detection of Active TB in HIV Exposed Children on CustomizedNanotrapR01AI113725 · NIAID · METHODIST HOSPITAL RESEARCH INSTITUTE · PI LABAER, JOSHUA · 2015 to 2018
$1.6M
Multiplexed quantification of circulating peptidomic signatures for EBOLA early diagnosisR21AI126361 · NIAID · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI LABAER, JOSHUA · 2017 to 2018
$373k
NIAID NIH HHS R01 AI113725NIAID NIH HHS R01 AI122932NIAID NIH HHS R21 AI126361NICHD NIH HHS R01 HD090927
6 · The paper itself

Abstract

Dark-field microscope (DFM) analysis of nanoparticle binding signal is highly useful for a variety of research and biomedical applications, but current applications for nanoparticle quantification rely on expensive DFM systems. The cost, size, limited robustness of these DFMs limits their utility for non-laboratory settings. Most nanoparticle analyses use high-magnification DFM images, which are labor intensive to acquire and subject to operator bias. Low-magnification DFM image capture is faster, but is subject to background from surface artifacts and debris, although image processing can partially compensate for background signal. We thus mated an LED light source, a dark-field condenser and a 20× objective lens with a mobile phone camera to create an inexpensive, portable and robust DFM system suitable for use in non-laboratory conditions. This proof-of-concept mobile DFM device weighs less than 400g and costs less than $2000, but analysis of images captured with this device reveal similar nanoparticle quantitation results to those acquired with a much larger and more expensive desktop DFMM system. Our results suggest that similar devices may be useful for quantification of stable, nanoparticle-based activity and quantitation assays in resource-limited areas where conventional assay approaches are not practical.

Indexed as

Biosensing TechniquesCell PhoneEquipment DesignHumansMicroscopyNanoparticlesDark field microscopeImageJImmunoassayMobile phoneNanoparticle

Identifiers

PMID28823976
PMCPMC5588877
OpenAlexW2746736820

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.