ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2018
Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 73 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Carbofix Pedicle Screw System: Randomized Clinical Trial to Evaluate the Clinical and Radiographic Outcomes of the Use of a Carbon Fiber Device Compared to Titanium Devices in Patients Undergoing Spinal Arthrodesis for Degenerative Spinal Diseases
Carbon Fiber Transpedicular Screws in Treatment of Spinal Metastatic Disease and Stereotactic Radiotherapy - a Prospective, Randomized Trial
Who cites it
73 citing papers in PubMed, 3 syntheses or guidelines pooled it, 134 citations in OpenAlex.
- Carbon fiber-PEEK pedicle screw instrumentation in spinal oncology: a retrospective case series, systematic review of the literature, and cost-effectiveness analysis.Journal of neuro-oncology · 2026Pooled it
- Carbon fiber-reinforced polyetheretherketone implants versus titanium implants for spinal tumors: a systematic review and meta-analysis.Journal of neuro-oncology · 2026Pooled it
- Clinical performance of implanted devices used in surgical treatment of patients with spinal tumors: a systematic review.BMC musculoskeletal disorders · 2024Pooled it
- Neurophysiological characteristics of carbon PEEK screws in patients with spinal metastatic disease.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Outcomes and Complications Associated With 191 Carbon Fiber Pedicle Screws in Spinal Oncology Patients.International journal of spine surgery · 2026Article
- Carbon fiber-reinforced peek versus titanium implants for the surgical treatment of spinal metastases: Evaluation of local disease control and quality of life.Journal of bone oncology · 2026Article
- Safety and efficacy of carbon fiber-reinforced polyetheretherketone implants in primary and metastatic spinal tumors: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Review
- Article
- Robot-Assisted "Postage-Stamp" Vertebrotomy for Spinal Tumor Resection: Case Report.Journal of clinical medicine · 2026Article
- Robot-Assisted Placement of Thoracic Carbon-Fiber-Reinforced Polyetheretherketone (CFR-Peek) Pedicle Screws in the Cervical Spine for Giant Cell Tumor: Technical Note.Bioengineering (Basel, Switzerland) · 2026Article
- Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026Review
- Electrical stimulation properties of carbon fiber versus titanium pedicle screw instrumentation: illustrative case.Journal of neurosurgery. Case lessons · 2026Article
- The Radiologists' Guide to Spinal Separation Surgery: What Does the Surgeon Want to Know?Diseases (Basel, Switzerland) · 2025Review
- CARBOMETASPINE: protocol for a multicenter, prospective, randomized controlled trial of carbonfiber spinal fixation in metastatic disease.BMC cancer · 2025Article
- Article
- Application of deformity principles in the management of spinal neoplasms: A Primer.North American Spine Society journal · 2025Article
- Enhanced strength and durability of long fiber type carbon fiber reinforced plastic rods over titanium alloy rods for spinal fixation.North American Spine Society journal · 2025Article
- En bloc resection, including the cord for tumor-free margin, in a multilevel osteosarcoma of the spine: 20-year disease-free survival. Illustrative case.Journal of neurosurgery. Case lessons · 2025Article
- Use of Carbon Fiber Implants to Improve the Safety and Efficacy of Radiation Therapy for Spine Tumor Patients.Brain sciences · 2025Review
- The Bony Density of the Pedicle Plays a More Significant Role in the Screw Anchorage Ability Than Other Regions of the Screw Trajectory.Orthopaedic surgery · 2025Article
13 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundProtocols including combination of surgery and radiotherapy are more and more frequent in the treatment of bone tumors of the spine. In metastatic disease, combination of surgery and radiotherapy is since long time accepted, as based on clinical evidence. In primary tumors, combination of surgery and radiotherapy can be considered in all the cases in which a satisfactory oncological margin cannot be achieved: high-grade malignancies, recurrent tumors, huge tumors expanding in an extracompartimental area, and when tumor-free margin requires unacceptable functional sacrifices. However, metal implants are an obstacle in the collaboration between surgeons and radiation oncologists. Carbon-fiber-reinforced polyethil-ether-ether-ketone (CFR-PEEK) composite implants could make easier and more effective the treatment as radiolucent and not interfering with ionizing radiation and accelerated particles. The purpose of this article is to report the preliminary results from a cohort of patients treated with CFR-PEEK and to evaluate the safety and the non-inferiority of the device respect the commonly used titanium implants. MATERIALS AND
methodsThis study concerns an ambispective cohort series of 34 tumor patients (14 metastases and 20 primaries, most of them recurrent) submitted to thoracic and lumbar spine fixation with a CFR-PEEK composite implants. Oncologic surgery was palliative decompression and fixation in 9 cases, tumor excision in 21, and enbloc resection in 4. Data collected for this preliminary report were all intraoperative remarks, incidence of complications, changes in neurological status, local control, and survival. All the cases were followed 6-36 months (mean 13 months).
resultsOnly one intraoperative screw breakage occurred out of 232 implanted screws. Pain control and neurological improvement were the early clinical results. Two sacral screws loosening were found at 9 and 12 months in multilevel constructs performed on multirecurrent tumors. Six local recurrences were early found thanks to the implant radiolucency. Radiation oncologists' opinion was favourable as concerning better treatment planning on CT and lacking of scattering effect during the treatment.
conclusionsNo artifacts on imaging studies mean early local recurrence detection. For radiation oncologists, no artifacts on imaging studies mean easier planning and no scattering effect means more effective and safe radiotherapy, particularly when particles are used. Moreover, it seems that the clinical use of CFR-PEEK composite implants may be safe and at least comparable with the commonly used titanium implants in terms of intraoperative complications, stability at weight bearing and at functional recovery. Larger patient series and longer follow-up are required to confirm these data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.