Evidence map›Paper›PMID 28815357›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2018

Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report.

Stefano Boriani, Giuseppe Tedesco, Lu Ming, Riccardo Ghermandi, Maurizio Amichetti, Piero Fossati, Marco Krengli, Loredana Mavilla, Alessandro Gasbarrini

2 registry-linked trialsAbstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 73 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
73citing papers in PubMed, 3 pooled it
8.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06209684 narecruitingnot on this mapstarted 2022, after this paper: background citation

Carbofix Pedicle Screw System: Randomized Clinical Trial to Evaluate the Clinical and Radiographic Outcomes of the Use of a Carbon Fiber Device Compared to Titanium Devices in Patients Undergoing Spinal Arthrodesis for Degenerative Spinal Diseases

TypeinterventionalSponsorIstituto Ortopedico RizzoliRan2022 to 2027Enrolled118ConditionsDegenerative Disc DiseaseArmsTitanium, Carbofix
NCT06293157 narecruitingnot on this mapstarted 2023, after this paper: background citation

Carbon Fiber Transpedicular Screws in Treatment of Spinal Metastatic Disease and Stereotactic Radiotherapy - a Prospective, Randomized Trial

TypeinterventionalSponsorCopernicus Memorial HospitalRan2023 to 2033Enrolled226ConditionsMetastatic Spinal Cord Compression, Metastasis SpineArmsTranspedicular spinal stabilization - carbon fibers-based implants, Transpedicular spinal stabilization - titanium implants, Stereotactic body radiotherapy
3 · Its place in the literature

Who cites it

73 citing papers in PubMed, 3 syntheses or guidelines pooled it, 134 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Neurophysiological characteristics of carbon PEEK screws in patients with spinal metastatic disease.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  5. Article
  6. Article
  7. Safety and efficacy of carbon fiber-reinforced polyetheretherketone implants in primary and metastatic spinal tumors: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Review
  8. Article
  9. Article
  10. Article
  11. Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
    Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article

13 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Stefano BorianiGSpine4 Spine Surgery Unit, IRCCS Galeazzi Orthopaedic Institute, Milano, Italy. sb@stefanoboriani.eu.
Giuseppe TedescoUnit of Oncologic and Degenerative Spine Surgery, Rizzoli Inst., Bologna, Italy.
Lu MingDepartment of Orthopedic, The Third Affiliated Hospital of Southern Medical University, Guangzhou, China.
Riccardo GhermandiUnit of Oncologic and Degenerative Spine Surgery, Rizzoli Inst., Bologna, Italy.
Maurizio AmichettiCenter for Protontherapy, USL Trento, Trento, Italy.
Piero FossatiCentro Nazionale di Adroterapia Oncologica (CNAO), Pavia, Italy.
Marco KrengliUniversity Department of Radiotherapy, Novara, Italy.
Loredana MavillaUnit of Health Management and Coding Control, Rizzoli Inst., Bologna, Italy.
Alessandro GasbarriniUnit of Oncologic and Degenerative Spine Surgery, Rizzoli Inst., Bologna, Italy.
Istituto Ortopedico Rizzoli · ITIstituto Ortopedico Galeazzi · ITNational Center for Oncological Hadrontherapy · ITThird Affiliated Hospital of Southern Medical University · CNUniversity of Trento · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProtocols including combination of surgery and radiotherapy are more and more frequent in the treatment of bone tumors of the spine. In metastatic disease, combination of surgery and radiotherapy is since long time accepted, as based on clinical evidence. In primary tumors, combination of surgery and radiotherapy can be considered in all the cases in which a satisfactory oncological margin cannot be achieved: high-grade malignancies, recurrent tumors, huge tumors expanding in an extracompartimental area, and when tumor-free margin requires unacceptable functional sacrifices. However, metal implants are an obstacle in the collaboration between surgeons and radiation oncologists. Carbon-fiber-reinforced polyethil-ether-ether-ketone (CFR-PEEK) composite implants could make easier and more effective the treatment as radiolucent and not interfering with ionizing radiation and accelerated particles. The purpose of this article is to report the preliminary results from a cohort of patients treated with CFR-PEEK and to evaluate the safety and the non-inferiority of the device respect the commonly used titanium implants. MATERIALS AND

methodsThis study concerns an ambispective cohort series of 34 tumor patients (14 metastases and 20 primaries, most of them recurrent) submitted to thoracic and lumbar spine fixation with a CFR-PEEK composite implants. Oncologic surgery was palliative decompression and fixation in 9 cases, tumor excision in 21, and enbloc resection in 4. Data collected for this preliminary report were all intraoperative remarks, incidence of complications, changes in neurological status, local control, and survival. All the cases were followed 6-36 months (mean 13 months).

resultsOnly one intraoperative screw breakage occurred out of 232 implanted screws. Pain control and neurological improvement were the early clinical results. Two sacral screws loosening were found at 9 and 12 months in multilevel constructs performed on multirecurrent tumors. Six local recurrences were early found thanks to the implant radiolucency. Radiation oncologists' opinion was favourable as concerning better treatment planning on CT and lacking of scattering effect during the treatment.

conclusionsNo artifacts on imaging studies mean early local recurrence detection. For radiation oncologists, no artifacts on imaging studies mean easier planning and no scattering effect means more effective and safe radiotherapy, particularly when particles are used. Moreover, it seems that the clinical use of CFR-PEEK composite implants may be safe and at least comparable with the commonly used titanium implants in terms of intraoperative complications, stability at weight bearing and at functional recovery. Larger patient series and longer follow-up are required to confirm these data.

Indexed as

AdolescentAdultAgedBenzophenonesBiocompatible MaterialsBone ScrewsCarbon FiberFemaleHumansKetonesMaleMiddle AgedNeoplasm Recurrence, LocalOrthopedic ProceduresPolyethylene GlycolsPolymersBenzophenonesBiocompatible MaterialsCarbon FiberKetonespolyetheretherketonePolyethylene GlycolsPolymersCarbon-fiber-reinforced PEEKRadiotherapyScattering effectSpinal metastasisSpine tumor

Identifiers

PMID28815357
OpenAlexW2748082597

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.