ArticleAnalytical and bioanalytical chemistry2017
Overcoming challenges in single particle inductively coupled plasma mass spectrometry measurement of silver nanoparticles.
Article in Analytical and bioanalytical chemistry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Determination of particle size and number concentrations in gold nanoparticle mixtures: an inter-method study using four analytical techniques (DLS, PTA, SEM and spICP-MS).Nanoscale advances · 2026Article
- Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics.Analytical chemistry · 2025Article
- Resistance mechanism of soluble microbial products to silver nanoparticles in activated sludge: adsorption, bonding and influencing factors.RSC advances · 2025Article
- Validation of a Method for Surveillance of Nanoparticles in Mussels Using Single-Particle Inductively Coupled Plasma-Mass Spectrometry.Journal of AOAC International · 2024Article
- An Approach Based on an Increased Bandpass for Enabling the Use of Internal Standards in Single Particle ICP-MS: Application to AuNPs Characterization.Nanomaterials (Basel, Switzerland) · 2023Article
- Evaluation of the Potential of Single Particle ICP-MS for the Accurate Measurement of the Number Concentration of AuNPs of Different Sizes and Coatings.Analytical chemistry · 2022Article
- Determination of the Transport Efficiency in spICP-MS Analysis Using Conventional Sample Introduction Systems: An Interlaboratory Comparison Study.Nanomaterials (Basel, Switzerland) · 2022Article
- Nanoparticle Delivery in Prostate Tumors Implanted in Mice Facilitated by Either Local or Whole-Body Heating.Fluids (Basel, Switzerland) · 2021Article
- Characterisation of Engineered Nanomaterials in Nano-Enabled Products Exhibiting Priority Environmental Exposure.Molecules (Basel, Switzerland) · 2021Article
- A Sensitive Single Particle-ICP-MS Method for CeOJournal of agricultural and food chemistry · 2021Article
- Fates of Au, Ag, ZnO, and CeOJournal of the American Society for Mass Spectrometry · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Single particle ICP-MS has evolved rapidly as a quantitative method for determining nanoparticle size and number concentration at environmentally relevant exposure levels. Central to the application of spICP-MS is a commonly used, but not rigorously validated, calibration approach based on the measured transport efficiency and the response of ionic standards. In this work, we present a comprehensive and systematic study of the accuracy, precision and robustness of spICP-MS using the rigorously characterized reference material (RM) 8017 (Polyvinylpyrrolidone Coated Nominal 75 nm Silver Nanoparticles), recently issued by the National Institute of Standards and Technology (NIST). We report for the first time, statistically significant differences in frequency-based and size-based measures of transport efficiency with NIST RM 8013 Gold Nanoparticles and demonstrate that the size-based measure of transport efficiency is more robust and yields accurate results for the silver nanoparticle RM relative to TEM-based reference values. This finding is significant, because the frequency-based method is more widely applied. Furthermore, we demonstrate that the use of acidified ionic standards improves measurement of ICP-MS Ag response, but does not degrade the accuracy of the results for AgNP suspensions in water or various other diluents. Approaches for controlling AgNP dissolution were investigated and are shown to effectively improve particle stability in dilute suspensions required for spICP-MS analysis, while minimally affecting the measured intensity and allowing for more robust analysis. This study is an important and necessary advancement toward full validation and adoption of spICP-MS by the broader research community. Graphical abstract Measurement challenges in spICP-MS analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.