ArticleAnnals of biomedical engineering2017
A Wireless Pressure Sensor for Continuous Monitoring of Intraocular Pressure in Conscious Animals.
Article in Annals of biomedical engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 24 citations in OpenAlex.
- Circadian Norepinephrine Rhythm Regulates Outflow Facility and IOP in Rat Eyes.Investigative ophthalmology & visual science · 2026Article
- Adrenergic Pathways Mediate Circadian IOP Rhythm in Rats.Investigative ophthalmology & visual science · 2026Article
- Additive framework of hormonal waves accounts for species and age differences in circadian intraocular pressure rhythm.Npj biological timing and sleep · 2026Article
- Design and Pilot Evaluation of an IoT-Based Blood Pressure Monitoring System for Rabbits.Bioengineering (Basel, Switzerland) · 2026Article
- Circadian IOP Rhythm in Rats Is Driven by Neural Signals From the Brain.Investigative ophthalmology & visual science · 2026Article
- Mechano- and Glucocorticoid-Sensitive TREK-1 Channels Regulate Conventional Outflow and Intraocular Pressure.Investigative ophthalmology & visual science · 2025Article
- A system for producing controlled elevation of intraocular pressure in awake Brown Norway rats.Experimental eye research · 2025Article
- Effect of Ambient Lighting on Intraocular Pressure Rhythms in Rats.Investigative ophthalmology & visual science · 2024Article
- Characterization of intraocular pressure variability in conscious rats.Experimental eye research · 2024Article
- A portable feedback-controlled pump for monitoring eye outflow facility in conscious rats.PloS one · 2023Article
- Simulation of gravity- and pump-driven perfusion techniques for measuring outflow facility of ex vivo and in vivo eyes.PloS one · 2023Article
- Effects of acute stress, general anesthetics, tonometry, and temperature on intraocular pressure in rats.Experimental eye research · 2021Article
- Optimization of orbital retraction during endoscopic transorbital approach via quantitative measurement of the intraocular pressure - [SevEN 006].BMC ophthalmology · 2021Article
- Using retinal function to define ischemic exclusion criteria for animal models of glaucoma.Experimental eye research · 2021Article
- Experimental glaucoma model with controllable intraocular pressure history.Scientific reports · 2020Article
- Recent Progress of Miniature MEMS Pressure Sensors.Micromachines · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
An important aspect of eye health in humans and animal models of human diseases is intraocular pressure (IOP). IOP is typically measured by hand with a tonometer, so data are sparse and sporadic and round-the-clock variations are not well characterized. Here we present a novel system for continuous wireless IOP and temperature measurement in small animals. The system consists of a cannula implanted in the anterior chamber of the eye connected to pressure sensing electronics that can be worn by rats or implanted in larger mammals. The system can record IOP with 0.3 mmHg accuracy and negligible drift at a rate of 0.25 Hz for 1-2 months on a regulated battery or indefinitely at rates up to 250 Hz via RF energy harvesting. Chronic recordings from conscious rats showed that IOP follows a diurnal rhythm, averaging 16.5 mmHg during the day and 21.7 mmHg at night, and that the IOP rhythm lags a diurnal rhythm in body temperature by 2.1 h. IOP and body temperature fluctuations were positively correlated from moment-to-moment as well. This technology allows researchers to monitor for the first time the precise IOP history of rat eyes, a popular model for glaucoma studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials